文献速递主动脉外科

离体双轴载荷测试分析主动脉生物力学显示零区弹性能量分布存在变异

Ex vivo biaxial load testing analysis of aortic biomechanics demonstrates variation in elastic energy distribution across the aortic zone zero.
PubMed 文献 · J Thorac Cardiovasc Surg · 2021-11-16

研究纳入65例择期升主动脉置换成人,取123份主动脉根部和近、远端升主动脉组织行双轴生物力学测试,获取拐点弹性能量并与患者特征及术前CT比较。拐点平均弹性能量为24.3±15.6 kJ/m3,根与近端、根与远端升主动脉间弹性能量显著增加,且随年龄增长而降低。年龄和区域是弹性能量最重要的预测因素,升主动脉腔内治疗结局评估须考虑部署区域及着陆区组织质量变异。

要点

  • 主动脉零区组织弹性能量在根部与近端、根部与远端升主动脉间显著增加。
  • 弹性能量随年龄增长而降低,年龄和区域是最重要预测因素。
  • 结缔组织病和双瓣主动脉瓣病史的差异在校正其他特征后减弱。

核心结论

  • 主动脉零区组织生物力学指标随区域和患者特征而变化。
  • 升主动脉腔内治疗结局评估必须密切考虑部署区域及着陆区长度上的组织质量变异。
  • 组织特征的区域变异应纳入现有的患者特异性主动脉力学模型。

研究设计与样本

  • 2018年2月至2021年1月,从65例择期升主动脉置换成人获取123份主动脉组织样本,取自主动脉根部及近端和远端升主动脉。
  • 行双轴生物力学测试获取拐点弹性能量,并与患者人口学和术前计算机断层扫描成像比较。
  • 使用B样条拟合系数模型探究弹性能量、区域与患者特征之间的关系。

主要发现

  • 拐点平均弹性能量为24.3 ± 15.6 kJ/m3。
  • 弹性能量在根部与近端升主动脉之间、根部与远端升主动脉之间显著增加,并随年龄增长而降低。
  • 结缔组织病病史和双瓣主动脉瓣所致差异显著,但在控制其他患者特征后减弱。
  • 在协变量中,年龄和区域是弹性能量最重要的预测因素。

临床怎么用

  • 作者认为,升主动脉腔内治疗结局评估必须密切考虑部署区域及着陆区长度上的组织质量变异。
  • 作者认为,组织特征的区域变异应纳入现有的患者特异性主动脉力学模型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We hypothesized that tissue characteristics vary significantly along zone zero, which may be reflected by regional differences in stored elastic energy. Our objectives were to (1) characterize the regional variation in stored elastic energy within tissues of the aortic zone zero and (2) identify the association between this variation and patient characteristics. METHODS: From February 2018 to January 2021, 123 aortic tissue samples were obtained from the aortic root and proximal and distal ascending aortas of 65 adults undergoing elective ascending aorta replacement. Biaxial biomechanics testing was performed to obtain tissue elastic energy at the inflection point and compared with patient demographics and preoperative computed tomography imaging. Coefficient models were fit using B-spline to interrogate the relationship among elastic energy, region, and patient characteristics. RESULTS: Mean elastic energy at inflection point was 24.3 ± 15.6 kJ/m3. Elastic energy increased significantly between the root and proximal, and root and distal ascending aorta and decreased with increasing age. Differences due to history of connective tissue disorder and bicuspid aortic valve were significant but diminished when controlled for other patient characteristics. Among covariates, age and region were found to be the most important predictors for elastic energy. CONCLUSIONS: Aortic tissue biomechanical metrics varied across regions and with patient characteristics within the aortic zone zero. Assessment of endovascular outcomes in the ascending aorta must closely consider the region of deployment and variable tissue qualities along the length of the landing zone. Regional variation in tissue characteristics should be incorporated into existing patient-specific models of aortic mechanics.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Durbak E, Tarraf S, Gillespie C, et al. Ex vivo biaxial load testing analysis of aortic biomechanics demonstrates variation in elastic energy distribution across the aortic zone zero. J Thorac Cardiovasc Surg. 2021. PMID: 35219518. doi:10.1016/j.jtcvs.2021.09.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。