主动脉瓣再植入术中主动脉瓣叶开窗患者的结局
本研究回顾了111例因主动脉根部动脉瘤行主动脉瓣再植入术且至少1个瓣叶开窗以细Gore-Tex缝线双层加固的患者,中位随访8.3年,15年主动脉瓣再干预累积发生率为4.8%,中度或重度主动脉瓣反流累积发生率为9.2%,与无开窗患者倾向性评分匹配后结果相似。结论认为加固开窗瓣叶游离缘安全,似乎不影响再植入术的耐久性。
要点
- 开窗瓣叶以细Gore-Tex缝线双层加固后,15年再干预累积发生率4.8%。
- 15年中度或重度主动脉瓣反流累积发生率9.2%。
- 与无开窗患者倾向性评分分析比较,随访至15年结果相似。
核心结论
- 使用Gore-Tex缝线加固开窗瓣叶的游离缘是安全的,似乎不会对主动脉瓣再植入术的耐久性产生不良影响。
研究设计与样本
- 回顾性分析所有因主动脉根部动脉瘤行主动脉瓣再植入术的患者,发现111例至少1个瓣叶开窗并以细Gore-Tex缝线双层加固,所有患者均前瞻性随访心脏影像,并与无开窗患者进行倾向性评分分析比较。
主要发现
- 中位随访8.3年,15年主动脉瓣再干预累积发生率为4.8%。
- 15年中度或重度主动脉瓣反流累积发生率为9.2%。
- 开窗患者与无开窗患者随访至15年的结局相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Aortic cusp fenestrations are common in patients with aortic root aneurysm, and their management during aortic valve repair remains controversial. We believe that fenestrations in the area of the commissures may rupture after reimplantation of the aortic valve because this operation increases the mechanical stress on the cusps. For this reason we have reinforced the free margin of the aortic cusp with fenestration with fine Gore-Tex sutures (WL Gore). This study examines the outcomes of reimplantation of the aortic valve in patients who had cusp fenestration reinforced with Gore-Tex sutures. METHODS: A review of all patients who had reimplantation of the aortic valve for aortic root aneurysm disclosed 111 patients who had at least 1 cusp fenestration reinforced with a double layer of a fine Gore-Tex suture. The outcomes of these patients were examined and compared with a group of patients without fenestration using propensity score analysis. All patients were followed prospectively with images of the heart. RESULTS: The median follow-up was 8.3 years. Overall the cumulative incidence of aortic valve reintervention at 15 years was 4.8% and the cumulative incidence of aortic insufficiency of moderate or severe degree was 9.2%. Comparison of outcomes of patients with and without fenestrations showed similar results up to 15 years of follow-up. CONCLUSIONS: Reinforcement of the free margins of cusps with fenestrations using Gore-Tex sutures is safe and does not seem to adversely affect the durability of reimplantation of the aortic valve.
引用
- David TE, Seidman MA, David CM, et al. Outcomes of Reimplantation of the Aortic Valve in Patients With Aortic Cusp Fenestration. Ann Thorac Surg. 2022. PMID: 35122724. doi:10.1016/j.athoracsur.2021.12.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。