三分支覆膜支架植入治疗急性非A非B型主动脉夹层
本研究评估三分支覆膜支架(TBSG)治疗急性非A非B型主动脉夹层的安全性和疗效,纳入2014年1月至2019年12月在本中心接受TBSG植入的50例患者。结果示院内及30天内无死亡,随访中夹层主动脉壁重塑良好,早期结局满意。
要点
- 50例急性非A非B型主动脉夹层患者接受TBSG植入,院内及30天内无死亡。
- 术后并发症包括肺炎12例、急性肾损伤6例(术前肾灌注不良4例)、短暂性脑损伤6例(术前脑灌注不良4例)、胸腔积液4例、心包积液2例。
- 随访中1例卒中,2例因TBSG水平以下残余夹层需二次介入治疗;所有支架定位良好、侧臂支架通畅,无逆行性主动脉夹层或I型内漏。
核心结论
- TBSG植入治疗急性非A非B型主动脉夹层死亡率和并发症发生率低,随访期间夹层主动脉壁重塑良好,该技术的早期结局满意。
研究设计与样本
- 单中心研究,纳入2014年1月至2019年12月在本中心接受TBSG植入的50例非A非B型主动脉夹层患者。
主要发现
- 院内及30天内无死亡。
- 术后并发症:肺炎12例,急性肾损伤6例(其中术前肾灌注不良4例),短暂性脑损伤6例(其中术前脑灌注不良4例),胸腔积液4例,心包积液2例。
- 随访期间1例发生卒中,2例因TBSG水平以下残余夹层需二次介入治疗。
- 所有植入的TBSG定位良好,所有侧臂覆膜支架完全通畅,未检测到逆行性主动脉夹层或I型内漏。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal treatment for acute non-A-non-B aortic dissection remains controversial. Triple-branched stent graft (TBSG) implantation has been used to treat acute type A aortic dissection. This study aimed to evaluate the safety and efficacy of TBSG as a treatment for acute non-A-non-B aortic dissection. METHODS: Fifty patients with non-A-non-B dissection received TBSG implantation in our center between January 2014 and December 2019. Early mortality, morbidity, and dissected aorta remodeling during follow-up were calculated. RESULTS: There were no deaths in-hospital or within 30 days. Postoperative complications included pneumonia (n = 12), acute kidney injury (n = 6; preoperative renal malperfusion, n = 4), transient cerebral injury (n = 6; preoperative cerebral malperfusion, n = 4), pleural effusion (n = 4), and pericardial effusion (n = 2). During follow-up, 1 patient experienced a stroke, and 2 patients required secondary interventional therapy for residual dissection below the level of the TBSG. All implanted TBSGs had good positioning, and all sidearm stent graft grafts were fully patent. No retrograde aortic dissection or type I endoleak was detected. CONCLUSIONS: TBSG implantation for acute non-A-non-B aortic dissection had a low incidence of mortality and morbidity, featuring good remodeling of the dissected aortic wall during follow-up. The early outcomes of this technique were satisfactory.
引用
- Li Q, Wu Q, Wu W, et al. Triple-Branched Stent Graft Implantation for Acute Non-A-non-B Aortic Dissection. Ann Thorac Surg. 2021. PMID: 34971594. doi:10.1016/j.athoracsur.2021.11.059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。