主动脉夹层中肾脏灌注不良的影像学特征
该回顾性队列研究纳入2010至2020年因急性主动脉夹层疑似内脏灌注不良转诊至本机构的161例患者,评估CT血管造影肾脏强化不对称与有创测压诊断肾脏灌注不良的关联。有创血管造影证实83%患者存在肾脏灌注不良,整体不对称肾脏强化对肾脏灌注不良的敏感性为65%、特异性为58%,整体和局灶强化缺陷均为独立预测因素。作者认为CT血管造影的肾脏差异强化对肾脏灌注不良有预测性但非决定性。
要点
- 整体不对称肾脏强化对肾脏灌注不良敏感性65%、特异性58%。
核心结论
- 在主动脉夹层患者中,CT血管造影所见的肾脏差异强化对肾脏灌注不良具有预测性,但并非决定性。
- CT血管造影有助于发现肾脏灌注不良,但其诊断需要密切监测并常需有创评估。
研究设计与样本
- 回顾性队列研究,纳入2010至2020年因急性夹层疑似内脏灌注不良转诊至本机构的所有患者,共分析161例。
- 通过视觉评估和肾皮质密度定量测量判定不对称肾脏强化,并在主动脉根部和肾动脉的有创血管造影中采集有创肾动脉压力。
- 采用逻辑回归评估肾脏灌注不良的独立预测因素。
主要发现
- 161例患者中男性占78%,A型夹层占52%。
- 有创血管造影证实83%的患者存在疑似肾脏灌注不良。
- 在有创血管造影期间无肾脏灌注不良的患者中,42%可见整体不对称肾脏强化。
- 不对称肾脏强化对肾脏灌注不良的敏感性为65%、特异性为58%。
临床怎么用
- 作者认为CT血管造影所见的肾脏差异强化对肾脏灌注不良具有预测性但非决定性,其诊断需要密切监测并常需有创评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Malperfusion syndrome accompanying aortic dissection is an independent predictor of death with in-hospital mortality rates >60%. Asymmetrically decreased renal enhancement on computed tomography angiography is often considered evidence of renal malperfusion. We investigated the associations between renal enhancement, baseline laboratory values and the diagnosis of renal malperfusion, as defined by invasive manometry, among patients with aortic dissection. METHODS: In this retrospective cohort study, we included all patients who were referred to our institution with acute dissection and suspected visceral malperfusion between 2010 and 2020. We determined asymmetric renal enhancement by visual assessment and quantitative density measurements of the renal cortex. We collected invasive renal artery pressures during invasive angiography at the aortic root and in the renal arteries. Logistic regression was performed to evaluate independent predictors of renal malperfusion. RESULTS: Among the 161 patients analysed, the majority of patients were male (78%) and had type A dissection (52%). Invasive angiography confirmed suspected renal malperfusion in 83% of patients. Global asymmetric renal enhancement was seen in 42% of patients who did not have renal malperfusion during invasive angiography. Asymmetrically decreased renal enhancement was 65% sensitive and 58% specific for renal malperfusion. Both global [odds ratio (OR) 4.43; 1.20-16.41, P = 0.03] and focal (OR 11.23; 1.12-112.90, P = 0.04) enhancement defects were independent predictors for renal malperfusion. CONCLUSIONS: In patients with aortic dissection, we found that differential enhancement of the kidney as seen on the computed tomography angiography is predictive, but not prescriptive for renal malperfusion. While detection of renal malperfusion is aided by computed tomography angiography, its diagnosis requires close monitoring and often invasive assessment.
引用
- van Bakel PAJ, Henry M, Kim KM, et al. Imaging features of renal malperfusion in aortic dissection. Eur J Cardiothorac Surg. 2022. PMID: 35019977. doi:10.1093/ejcts/ezab555
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。