文献速递冠心病外科

缺血性心肌病患者体外循环与非体外循环冠状动脉旁路移植术的长期结局

Long-term Outcomes After On-Pump vs Off-Pump Coronary Artery Bypass Grafting for Ischemic Cardiomyopathy.
PubMed 文献 · Ann Thorac Surg · 2022-01-24

该研究为STICH试验的事后分析,纳入768例接受单纯CABG的缺血性心肌病(LVEF≤35%)患者,按1:2倾向性评分匹配比较非体外循环与体外循环手术。匹配队列(152例非体外循环 vs 304例体外循环)中,非体外循环组多支动脉桥比例更高(17.1% vs 8.6%,P=.01),完全血运重建率更低(34.2% vs 17.1%,P<.001);30天死亡率(3.3% vs 5.3%,P=.34)和全因死亡风险(HR 0.82;95%CI 0.61-1.09)两组相似。

要点

  • 非体外循环组多支动脉桥比例高于体外循环组(17.1% vs 8.6%,P=.01)。
  • 非体外循环组不完全血运重建率高于体外循环组(34.2% vs 17.1%,P<.001)。
  • 两组30天死亡率(3.3% vs 5.3%,P=.34)及全因死亡风险(HR 0.82;95%CI 0.61-1.09)相似。

核心结论

  • 在缺血性心肌病患者中,非体外循环CABG的30天死亡率和长期生存与体外循环CABG相当,且围术期并发症发生率似乎更低。

研究设计与样本

  • STICH试验的事后分析,纳入接受单纯CABG的缺血性心肌病(冠心病伴LVEF≤35%)患者,采用1:2倾向性评分匹配队列比较围术期和长期结局。
  • 共纳入768例患者(2002年7月至2007年5月手术),其中非体外循环152例(19.8%),体外循环616例(80.2%);匹配队列为非体外循环152例和体外循环304例。

主要发现

  • 匹配队列中,非体外循环组多支动脉桥比例为17.1%,体外循环组为8.6%(P=.01)。
  • 非体外循环组不完全血运重建比例为34.2%,体外循环组为17.1%(P<.001)。
  • 30天死亡率非体外循环组为3.3%,体外循环组为5.3%(P=.34)。
  • 中位随访8.7年,非体外循环组全因死亡风险HR为0.82(95%CI 0.61-1.09)。
  • 估计全因死亡率:1年非体外循环组12.5% vs 体外循环组11.9%,5年32% vs 32.8%,10年51.4% vs 62.3%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A post-hoc analysis of the Surgical Treatment for Ischemic Heart Failure (STICH) trial was performed to evaluate the perioperative and long-term outcomes after off-pump vs on-pump coronary artery bypass graft surgery in patients with ischemic cardiomyopathy (coronary artery disease with left ventricular ejection fraction 35% or less). METHODS: Patients who underwent isolated coronary artery bypass graft surgery were enrolled from the STICH trial. Operative details, perioperative outcomes, and long-term outcomes were compared in a 1-to-2 propensity score matching cohort. The primary outcome was death from any cause. RESULTS: Among 768 included patients operated on between July 2002 and May 2007, 152 (19.8%) received off-pump and 616 (80.2%) received on-pump coronary artery bypass graft surgery. In the 1-to-2 matched cohort (152 off pump and 304 on pump), off pump was associated with a higher prevalence of multiple arterial grafting (17.1% vs 8.6%, P = .01) and incomplete revascularization (34.2% vs 17.1%, P < .001). The overall 30-day mortality (3.3% vs 5.3%, P = .34) was comparable between the two groups. After a median follow-up of 8.7 years, off-pump surgery was associated with a similar risk of death from any cause (hazard ratio 0.82; 95% confidence interval, 0.61 to 1.09), with comparable estimated all-cause mortality at 1 year (12.5% vs 11.9%), 5 years (32% vs 32.8%), and 10 years (51.4% vs 62.3%). No significant interaction was detected in the subgroup analyses of incomplete revascularization, multiple arterial grafting, and three-vessel disease. CONCLUSIONS: In patients with ischemic cardiomyopathy, off-pump coronary artery bypass graft surgery could be performed with comparable 30-day mortality and similar long-term survival, and appears to have a lower incidence of perioperative morbidities.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Zhou Z, Liang M, Zhuang X, et al. Long-term Outcomes After On-Pump vs Off-Pump Coronary Artery Bypass Grafting for Ischemic Cardiomyopathy. Ann Thorac Surg. 2022. PMID: 35085524. doi:10.1016/j.athoracsur.2021.12.063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。