文献速递冠心病外科

生物修复性聚合物冠状动脉旁路移植移植物在绵羊模型中的一年表现:早期生物力学与晚期系列定量血流比值的相关性

One-year performance of biorestorative polymeric coronary bypass grafts in an ovine model: correlation between early biomechanics and late serial Quantitative Flow Ratio.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

本研究在绵羊模型中探究基线机械因素对用于冠状动脉旁路移植的修复性导管通畅性的影响,对7只动物的69个移植物几何结构进行分析,在3个月和12个月随访时评估弯曲角度、浅层壁应变及最小和最大内皮剪切应力与节段定量血流比值变化的相关性。结果显示早期异常机械因素与晚期血流指标存在关联,最小和最大内皮剪切应力与3个月定量血流比值变化的相关性最强(ρ=0.30,95%CI [-0.05 to 0.56] 和 ρ=0.27,95%CI [-0.05 to 0.54])。

要点

  • 基线弯曲角度最大的节段与12个月时最高的定量血流比值变化共定位。
  • 基线浅层壁应变最高的部位与3个月时吻合口两端的定量血流比值变化共定位。
  • 基线的内皮剪切应力与随访时更高的定量血流比值变化存在地形学关联。

核心结论

  • 尽管移植物数量有限,本研究提示早期异常机械因素与移植物晚期血流指标之间存在关联。
  • 理解机械特性可能有助于改进这种新型导管。

研究设计与样本

  • 在绵羊模型中,对7只动物的69个移植物几何结构进行分析,于基线(1个月)血管造影上逐帧重建三维移植物模型,由对晚期随访设盲的核心实验室评估4项机械因素(弯曲角度、浅层壁应变、最小和最大内皮剪切应力)。
  • 晚期通畅性通过定量血流比值(QFR®)记录,反映移植物的生理状态;在每个移植物的10个等长节段上分析4项机械因素与节段定量血流比值变化(△QFR)的相关性。

主要发现

  • 12个月时最高的△QFR与基线弯曲角度最大的移植物节段共定位。
  • 3个月时较高的△QFR位于吻合口两端,并与基线浅层壁应变最高处共定位。
  • 基线高内皮剪切应力与最新随访时更高的△QFR存在地形学关联。
  • 最小和最大内皮剪切应力与3个月时△QFR的相关性在这些参数中最强(ρ=0.30,95%CI [-0.05 to 0.56] 和 ρ=0.27,95%CI [-0.05 to 0.54])。

局限性

  • 尽管移植物数量有限,本研究提示早期异常机械因素与移植物晚期血流指标之间存在关联。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to investigate the impact of mechanical factors at baseline on the patency of a restorative conduit for coronary bypass grafts in an ovine model at serial follow-up up to 1 year. METHODS: The analyses of 4 mechanical factors [i.e. bending angle, superficial wall strain and minimum and maximum endothelial shear stress (ESS)] were performed in 3D graft models reconstructed on baseline (1-month) angiograms frame by frame by a core laboratory blinded for the late follow-up. The late patency was documented by Quantitative Flow Ratio (QFR®) that reflects the physiological status of the graft. The correlation between 4 mechanical factors and segmental QFR (△QFR) were analysed on 10 equal-length segments of each graft. RESULTS: A total of 69 graft geometries of 7 animals were performed in the study. The highest △QFR at 12 months was colocalized in segments of the grafts with the largest bending angles at baseline. Higher △QFR at 3 months were both at the anastomotic ends and were colocalized with the highest superficial wall strain at baseline. High baseline ESS was topographically associated with higher △QFR at the latest follow-up. Correlations of minimum and maximum ESS with △QFR at 3 months were the strongest among these parameters (ρ = 0.30, 95% CI [-0.05 to 0.56] and ρ = 0.27, 95% CI [-0.05 to 0.54], respectively). CONCLUSIONS: Despite the limited number of grafts, this study suggests an association between early abnormal mechanical factors and late flow metrics of the grafts. The understanding of the mechanical characteristics could help to improve this novel conduit.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Wu X, Ono M, Poon EKW, et al. One-year performance of biorestorative polymeric coronary bypass grafts in an ovine model: correlation between early biomechanics and late serial Quantitative Flow Ratio. Eur J Cardiothorac Surg. 2022. PMID: 35022681. doi:10.1093/ejcts/ezab554

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。