左心室大小对离心流左心室辅助装置植入后结局的影响
单中心313例离心流左心室辅助装置植入患者队列分析显示,术前左心室舒张末期内径≤59 mm者生存率较低(1年71% vs 85%,2年58% vs 80%,P=0.003),且临时右心室机械支持需求、晚期右心衰竭、消化道出血及低流量报警再入院率均较高。
要点
- 术前左心室舒张末期内径≤59 mm与离心流左心室辅助装置植入后生存率较低相关。
- 左心室舒张末期内径≤59 mm组临时右心室机械支持需求(11.5% vs 1.9%,P=0.002)及晚期右心衰竭发生率(23% vs 12%,P=0.02)较高。
- 多变量分析显示较小左心室舒张末期内径、高龄、高血尿素氮及高胆红素水平是生存较差的独立预测因素。
核心结论
- 在接受离心流左心室辅助装置的患者中,术前较小的左心室舒张末期内径(≤59 mm)与较低的生存率和较高的不良结局发生率相关。
研究设计与样本
- 单中心队列研究,纳入313例接受离心流左心室辅助装置的患者,采用最大选择log-rank统计量确定左心室舒张末期内径截断值,并据此将队列分为2组。
主要发现
- 左心室舒张末期内径≤59 mm组(N=52)与>59 mm组(N=261)相比,1年生存率71% vs 85%,2年生存率58% vs 80%(P=0.003)。
- 左心室舒张末期内径≤59 mm组临时右心室机械支持需求为11.5% vs 1.9%(P=0.002)。
- 左心室舒张末期内径≤59 mm组出院时泵流量较低(3.8 vs 4.2 l/min,P=0.005),晚期右心衰竭发生率较高(23% vs 12%,P=0.02)。
- 左心室舒张末期内径≤59 mm组消化道出血发生率较高(0.416 vs 0.256事件/患者年,P=0.025),因低流量报警再入院率较高(0.429 vs 0.240事件/患者年,P=0.007)。
- 多变量分析显示较小左心室舒张末期内径、高龄、高血尿素氮和高胆红素水平是生存较差的独立预测因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The influence of preoperative left ventricular size in outcomes following centrifugal-flow left ventricular assist device (LVAD) implantation has not been well characterized. METHODS: A cohort of 313 patients who received a centrifugal-flow LVAD at a single institution was analysed. Using a maximally selected log-rank statistic, we investigated whether a left ventricular end-diastolic dimension (LVEDD) cut-off point was associated with worse outcomes. The cohort was then divided in 2 groups based on the LVEDD cut-off point. RESULTS: An LVEDD cut-off point of 59 mm was found to predict worse survival. Smaller LVEDD patients (≤59 mm, N = 52) were older and more likely to have a history of coronary artery disease compared those with a larger LVEDD (>59 mm, N = 261). Smaller LVEDD patients had lower survival compared to larger LVEDD patients (71% vs 85% at 1 year and 58% vs 80% at 2 years, P = 0.003). The need for temporary right ventricular mechanical support was significantly higher in the smaller LVEDD cohort (11.5% vs 1.9%, P = 0.002). Pump flows at time of discharge were lower in the smaller LVEDD group (3.8 vs 4.2 l/min, P = 0.005), who also had a higher incidence of late right ventricular failure (23% vs 12%, P = 0.02), higher rates of gastrointestinal bleeding (0.416 vs 0.256 events per patient-year, P = 0.025) and higher readmissions secondary to low flow alarms (0.429 vs 0.240 events per patient-year, P = 0.007). Multivariable analysis demonstrated that smaller LVEDD, older age, high BUN and high bilirubin levels were independent predictors of worse survival. CONCLUSIONS: In patients receiving a centrifugal-flow LVAD, smaller preoperative LVEDD (≤59 mm) was associated with lower survival and higher incidence of adverse outcomes.
引用
- Molina E, Jain A, Ahmed S, et al. The impact of left ventricular size on outcomes after centrifugal-flow left ventricular assist device implantation. Eur J Cardiothorac Surg. 2022. PMID: 34788417. doi:10.1093/ejcts/ezab480