文献速递主动脉外科

急诊转运中 thoracic aortic disease(胸主动脉疾病)的误诊常见

Misdiagnosis of Thoracic Aortic Disease Occurs Commonly in Emergency Transfers.
PubMed 文献 · Ann Thorac Surg · 2021-11-25

本研究回顾2008年1月至2018年5月因疑似急性主动脉综合征(AAS)急诊转运至三级中心的784例患者,比较转运诊断与实际诊断,发现89例(11.4%)存在误诊,全部源于影像学判读错误,其中运动伪影14例(16%)、术后改变22例(25%)为常见误诊来源,64例(72%)在本中心重复扫描。

要点

  • 疑似AAS急诊转运患者中误诊率为11.4%(89/784)。
  • 误诊患者中27%(24例)为Stanford A型与B型夹层分类错误。
  • 72%(64例)因外院影像质量或可及性限制在本中心重复扫描。

核心结论

  • 尽管AAS误诊率较前十年似乎有所改善,但通过「Think Aorta」等宣传活动提高医生意识仍有改进空间;基于网络的集中影像可能避免不必要的急诊转运带来的高昂代价。

研究设计与样本

  • 回顾性查询本机构转运中心数据库,纳入2008年1月至2018年5月因疑似AAS或胸主动脉瘤急诊转运的患者,共784例分类为疑似AAS急诊转运。
  • 通过复习转诊机构与本中心的医生记录及影像报告,比较转运诊断与实际诊断。

主要发现

  • 患者平均年龄62岁,男性478例(61%)。
  • 转运诊断与实际诊断存在差异者89例(11.4%)。
  • 误诊患者中,Stanford A型或B型夹层分类错误24例(27%)。
  • 转诊诊断为主动脉夹层的患者中,23例(26%)未发现夹层;因包裹性/濒临破裂转运的患者中,18例(20%)未发现破裂征象。
  • 所有误诊均继发于影像学判读错误,运动伪影14例(16%)和术后改变22例(25%)为常见诊断错误来源;64例(72%)因外院影像可及性有限或质量欠佳在本中心重复扫描。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Acute aortic syndromes (AASs) are prone to misdiagnosis by facilities with limited diagnostic experience. We assessed long-term trends in misdiagnosis among patients transferred to a tertiary care facility with presumed AASs. METHODS: Our institutional transfer center database was queried for emergency transfers in patients with a diagnosis of AASs or thoracic aortic aneurysm between January 2008 and May 2018. There were 784 patients classified as emergency transfer for presumed AAS. Transferring diagnosis and actual diagnosis were compared through a review of physician notes and radiology reports from referring facilities and our center. RESULTS: Mean age was 62 years, with 478 (61%) men. Differences in transferring diagnosis and actual diagnosis were identified in 89 patients (11.4%). Among misdiagnosed patients, the wrong classification of Stanford type A or type B dissections was identified among 24 patients (27%). No dissection was found in 23 patients (26%) with a referring diagnosis of aortic dissection. No signs of rupture were found in 18 patients (20%) transferred for contained/impending rupture. All misdiagnoses were secondary to misinterpretation of radiographic imaging, with motion artifacts in 14 (16%) and postsurgical changes in 22 (25%) being common sources of diagnostic error. Repeat scans were performed in 64 patients (72%) at our facility due to limited access to or suboptimal quality of outside imaging. CONCLUSIONS: Although AASs misdiagnosis rates appear to be improving from the prior decade, there are opportunities for improved physician awareness through campaigns such as "Think Aorta." Centralized web-based imaging may prevent the costly hazards of unnecessary emergency transfer.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Holmes HR, Neal D, Freeman K, et al. Misdiagnosis of Thoracic Aortic Disease Occurs Commonly in Emergency Transfers. Ann Thorac Surg. 2021. PMID: 34838743. doi:10.1016/j.athoracsur.2021.11.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。