文献速递区域麻醉与超声

腰椎棘间韧带解剖:与阻力消失法硬膜外置管相关的发现

Anatomy of the lumbar interspinous ligament: findings relevant to epidural insertion using loss of resistance.
PubMed 文献 · Reg Anesth Pain Med · 2021-10-22

该研究对14具经甲醛固定的供体腰椎(T12至S1)进行MRI成像后沿倾斜轴面解剖,测量73个椎间隙的棘间韧带及棘上韧带形态。结果显示韧带轴面呈双凹形,中段变窄,75%存在脂肪填充间隙,多位于前部并与黄韧带连接处相关;MRI检测间隙以解剖为金标准敏感度100%、特异度94.4%。这些解剖特征可能解释阻力消失法假阳性或不确定的原因。

要点

  • 腰椎棘间韧带轴面呈双凹形,中段宽度仅4.5mm,穿刺阻力可能变化。
  • 75%椎间隙存在脂肪填充间隙,多位于前部,或致阻力消失假阳性。
  • MRI检测间隙敏感度100%、特异度94.4%,可术前评估韧带结构。

核心结论

  • 腰椎棘间韧带与棘上韧带轴面呈双凹形,常存在脂肪填充间隙,尤其在前部,这些特征可能是阻力消失法假阳性或不确定的解剖基础。

研究设计与样本

  • 对14具经甲醛固定的供体腰椎(T12至S1)先进行MRI成像,再沿与腰椎间隙对齐的倾斜轴面进行解剖观察和测量。

主要发现

  • 在73个椎间隙中,腰椎棘间韧带加棘上韧带长度中位数(IQR)为29.7 mm(25.5-33.4)。
  • 后部宽度中位数(IQR)为9.2 mm(7.7-11.9),中部变窄为4.5 mm(3.0-6.8),前部宽度为7.3 mm(5.7-9.8)。
  • 55个(75%)椎间隙存在脂肪填充间隙;51个前部间隙中49个(67%)与黄韧带连接处相关。
  • 间隙长度和宽度中位数(IQR)分别为3.5 mm(2.5-5.1)和1.1 mm(0.9-1.7)。

关键数值与推荐

  • MRI检测间隙以解剖为金标准:敏感度100%(95%CI 93.5-100),特异度94.4%(72.7-99.9),阳性预测值98.2%(90.4-100),阴性预测值100%(80.5-100)。

临床怎么用

  • 硬膜外穿刺遇阻力消失不确定时,可考虑棘间韧带脂肪间隙导致假阳性的可能,结合解剖特征调整进针。

局限性

  • 研究基于14具甲醛固定供体腰椎,样本量有限,结果外推至活体需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: The 'loss of resistance' technique is used to determine entry into the epidural space, often by a midline needle in the interspinous ligament before the ligamentum flavum. Anatomical explanations for loss of resistance without entry into the epidural space are lacking. This investigation aimed to improve morphometric characterization of the lumbar interspinous ligament by observation and measurement at dissection and from MRI. METHODS: Measurements were made on 14 embalmed donor lumbar spines (T12 to S1) imaged with MRI and then dissected along a tilted axial plane aligned with the lumbar interspace. RESULTS: In 73 interspaces, median (IQR) lumbar interspinous plus supraspinous ligament length was 29.7 mm (25.5-33.4). Posterior width was 9.2 mm (7.7, 11.9), with narrowing in the middle (4.5 mm (3.0, 6.8)) and an anterior width of 7.3 mm (5.7, 9.8).Fat-filled gaps were present within 55 (75%). Of 51 anterior gaps, 49 (67%) were related to the ligamenta flava junction. Median (IQR) gap length and width were 3.5 mm (2.5, 5.1) and 1.1 mm (0.9, 1.7).Detection of gaps with MRI had 100% sensitivity (95% CI 93.5 to 100), 94.4% specificity (72.7, 99.9), 98.2% (90.4, 100) positive predictive value and 100% (80.5, 100) negative predictive value against dissection as the gold standard. CONCLUSIONS: The lumbar interspinous ligament plus supraspinous ligament are biconcave axially. It commonly has fat-filled gaps, particularly anteriorly. These anatomical features may form the anatomical basis for false or equivocal loss of resistance.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Lawrence S, Llewellyn S, Hunt H, et al. Anatomy of the lumbar interspinous ligament: findings relevant to epidural insertion using loss of resistance. Reg Anesth Pain Med. 2021. PMID: 34686581. doi:10.1136/rapm-2021-103014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。