文献速递气道管理

经鼻高流量氧疗与气管插管在喉显微手术中氧合效果的非劣效性随机研究

Efficacy of high-flow nasal oxygenation compared with tracheal intubation for oxygenation during laryngeal microsurgery: a randomised non-inferiority study.
PubMed 文献 · Br J Anaesth · 2021-10-20

这项随机非劣效性研究比较了经鼻高流量氧疗(HFNC)与气管插管在喉显微手术中的氧合效果。共130例患者随机分组,118例纳入分析。主要终点为手术前30分钟最低脉搏血氧饱和度(SpO2),HFNC组为100(98-100)%,气管插管组为100(100-100)%,平均差异-1.4%(95%CI:-2.4%至-0.3%),未能确认非劣效性(非劣效界值2%)。HFNC组高碳酸血症和抢救干预发生率更高。

要点

  • HFNC在喉显微手术中维持氧饱和度未达到非劣效于气管插管。
  • HFNC组去饱和、高碳酸血症及抢救干预发生率高于气管插管组。
  • 即使短时气道手术,使用HFNC也需谨慎监测。

核心结论

  • HFNC氧合在喉显微手术中维持氧饱和度方面非劣效于气管插管未能成立。
  • 与气管插管相比,HFNC组去饱和、高碳酸血症和抢救干预更频繁,应谨慎使用并加强监测。

研究设计与样本

  • 随机非劣效性研究,纳入≥20岁全身麻醉及神经肌肉阻滞下喉显微手术患者,随机分为HFNC组或气管插管组。
  • 共130例随机,118例纳入分析(HFNC组n=56,气管插管组n=62)。
  • 主要终点为手术前30分钟最低SpO2;次要终点包括去饱和(SpO2<95%)、高碳酸血症(经皮CO2≥8.7 kPa)和抢救干预发生率。

主要发现

  • 最低SpO2:HFNC组100(98-100)%,气管插管组100(100-100)%,平均差异-1.4%(95%CI:-2.4%至-0.3%),未能确认非劣效性(非劣效界值2%)。
  • HFNC组手术结束时经皮CO2峰值和呼气末CO2高于气管插管组。
  • HFNC组去饱和、高碳酸血症和抢救干预发生率高于气管插管组。

关键数值与推荐

  • 非劣效性界值为2%,平均差异95%CI下限-2.4%超过界值,非劣效性未成立。
  • 去饱和定义为SpO2<95%;高碳酸血症定义为经皮CO2≥8.7 kPa。

临床怎么用

  • 喉显微手术中若选用HFNC替代气管插管,应加强SpO2和CO2监测,并做好抢救干预准备。
  • 鉴于去饱和和高碳酸血症风险较高,HFNC不宜常规替代气管插管用于此类手术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Oxygenation via a high-flow nasal cannula (HFNC) can be an alternative to tracheal intubation during short apnoeic procedures. This randomised, non-inferiority study assessed the efficacy of HFNC compared with tracheal intubation in laryngeal microsurgery. METHODS: Patients (≥20 yr old) undergoing laryngeal microsurgery under general anaesthesia and neuromuscular blockade were randomised to either the HFNC or tracheal intubation groups. The primary endpoint was lowest pulse oxygen saturation (SpO2) during the first 30 min of surgery. Secondary endpoints included incidence of desaturation (SpO2 <95%), hypercarbia (transcutaneous carbon dioxide [CO2] ≥8.7 kPa), and rescue intervention. RESULTS: Amongst 130 patients randomised, 118 were included in the analysis. The lowest SpO2 was 100 (98-100)% in the HFNC group (n=56) and 100 (100-100)% in the tracheal intubation group (n=62), with a mean difference of -1.4% (95% confidence interval: -2.4% and -0.3%), failing to confirm non-inferiority with a non-inferiority margin of 2%. The peak transcutaneous CO2 and end-tidal CO2 at the end of surgery were higher in the HFNC group compared with the tracheal intubation group. Incidences of desaturation, hypercarbia, and rescue intervention were more frequent in patients receiving HFNC compared with tracheal intubation. CONCLUSIONS: HFNC oxygenation was not non-inferior to tracheal intubation for maintaining oxygen saturation during laryngeal microsurgery. Considering more frequent desaturation, hypercarbia, and requirement for rescue intervention compared with tracheal intubation, HFNC should be used with cautious monitoring even for short duration airway surgery. CLINICAL TRIAL REGISTRATION: NCT03629353.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Min SH, Yoon H, Huh G, et al. Efficacy of high-flow nasal oxygenation compared with tracheal intubation for oxygenation during laryngeal microsurgery: a randomised non-inferiority study. Br J Anaesth. 2021. PMID: 34688473. doi:10.1016/j.bja.2021.09.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。