文献速递气道管理

手动面罩通气气溶胶生成的定量评估

Quantitative evaluation of aerosol generation during manual facemask ventilation.
PubMed 文献 · Anaesthesia · 2021-10-26

本研究在麻醉患者中监测手动面罩通气(含故意漏气)的气溶胶浓度,并与潮气呼吸和咳嗽对比。结果显示面罩通气(无论是否漏气)气溶胶浓度远低于潮气呼吸和咳嗽,提示面罩通气不应被视为气溶胶生成操作。

要点

  • 面罩通气(含故意漏气)气溶胶浓度显著低于潮气呼吸和咳嗽。
  • 无漏气面罩通气气溶胶浓度比潮气呼吸低64倍(p=0.001)。
  • 面罩通气峰值浓度比咳嗽低至少10倍,不应视为气溶胶生成操作。

核心结论

  • 面罩通气即使故意漏气也不产生高水平生物气溶胶,不应归类为气溶胶生成操作。

研究设计与样本

  • 在麻醉患者中监测常规面罩通气及故意漏气面罩通气的气溶胶,并与潮气呼吸和咳嗽对比,在超净手术室进行。

主要发现

  • 潮气呼吸(11例)中位粒子计数191(IQR 77-486,范围4-1313)粒子·L⁻¹,背景2(1-5 [0-13])粒子·L⁻¹,p=0.002。
  • 无漏气面罩通气中位气溶胶浓度3(0-9 [0-43])粒子·L⁻¹,比潮气呼吸低64倍(p=0.001)。
  • 故意漏气面罩通气中位浓度11(7-26 [1-62])粒子·L⁻¹,比潮气呼吸低17倍(p=0.002)。
  • 无漏气面罩通气峰值浓度60(0-60 [0-120])粒子·L⁻¹,比咳嗽低20倍(p=0.002)。
  • 漏气面罩通气峰值浓度120(60-180 [60-480])粒子·L⁻¹,比咳嗽低10倍(p=0.001)。

临床怎么用

  • 面罩通气不应被视为气溶胶生成操作,可据此调整防护策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Manual facemask ventilation, a core component of elective and emergency airway management, is classified as an aerosol-generating procedure. This designation is based on one epidemiological study suggesting an association between facemask ventilation and transmission during the SARS-CoV-1 outbreak in 2003. There is no direct evidence to indicate whether facemask ventilation is a high-risk procedure for aerosol generation. We conducted aerosol monitoring during routine facemask ventilation and facemask ventilation with an intentionally generated leak in anaesthetised patients. Recordings were made in ultraclean operating theatres and compared against the aerosol generated by tidal breathing and cough manoeuvres. Respiratory aerosol from tidal breathing in 11 patients was reliably detected above the very low background particle concentrations with median [IQR (range)] particle counts of 191 (77-486 [4-1313]) and 2 (1-5 [0-13]) particles.l-1 , respectively, p = 0.002. The median (IQR [range]) aerosol concentration detected during facemask ventilation without a leak (3 (0-9 [0-43]) particles.l-1 ) and with an intentional leak (11 (7-26 [1-62]) particles.l-1 ) was 64-fold (p = 0.001) and 17-fold (p = 0.002) lower than that of tidal breathing, respectively. Median (IQR [range]) peak particle concentration during facemask ventilation both without a leak (60 (0-60 [0-120]) particles.l-1 ) and with a leak (120 (60-180 [60-480]) particles.l-1 ) were 20-fold (p = 0.002) and 10-fold (0.001) lower than a cough (1260 (800-3242 [100-3682]) particles.l-1 ), respectively. This study demonstrates that facemask ventilation, even when performed with an intentional leak, does not generate high levels of bioaerosol. On the basis of this evidence, we argue facemask ventilation should not be considered an aerosol-generating procedure.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Shrimpton AJ, Brown JM, Gregson FKA, et al. Quantitative evaluation of aerosol generation during manual facemask ventilation. Anaesthesia. 2021. PMID: 34700360. doi:10.1111/anae.15599

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。