胸部创伤中连续竖脊肌平面导管的安全性:回顾性队列研究
结果显示无立即并发症,导管失败率为7.7%(每100根导管8.4,95%CI 5.1-13.9),轻微晚期并发症发生率为每1000根导管16.7(95%CI 6.1-45.5)。结论支持区域麻醉学会关于该技术安全性的声明。
要点
- 竖脊肌平面导管用于肋骨骨折镇痛未发生立即并发症。
- 导管失败率为7.7%,每100根导管8.4(95%CI 5.1-13.9)。
- 轻微晚期并发症发生率低,为每1000根导管16.7。
核心结论
- 竖脊肌平面阻滞导管是低风险镇痛技术,支持区域麻醉学会的安全性声明。
主要发现
- 共224例患者接受244根连续竖脊肌平面导管,置入后无低血压、低氧血症、局部麻醉药全身毒性或气胸等立即并发症。
- 7.7%的导管因导管失败而移除(每100根导管8.4,95%CI 5.1-13.9),失败率为每1000导管日1.9(95%CI 1.1-6.7)。
- 晚期并发症包括2例导管部位红斑和2例小血肿无需干预,轻微晚期并发症发生率为每1000根导管16.7(95%CI 6.1-45.5)。
临床怎么用
- 对于胸部创伤肋骨骨折患者,竖脊肌平面阻滞导管可作为低风险镇痛选择。
- 在凝血功能异常或全身性感染情况下仍可考虑实施该技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The erector spinae block is an efficacious analgesic option for the management of rib fracture--related pain. Despite there being minimal published data specifically addressing the safety profile of this block, many societies have made statements regarding its safety and its use as an alternative to traditional regional anesthesia techniques in patients at risk of complications. The primary aim of this study was to characterize the safety profile of erector spinae plane block catheters by determining the incidence of early complications. The secondary aim of this study was to characterize the incidence of late adverse events, as well as the erector spinae plane block catheter failure rate. METHODS: We analyzed electronic medical record data of patients who had an erector spinae plane block catheter inserted for the management of rib fractures between November 2017 and September 2020. To assess early adverse events, data collection included hypotension, hypoxemia, local anesthetic systemic toxicity, and pneumothorax thought to be associated with erector spinae plane block catheter insertion. Late complications included catheter site infection and catheter site hematoma. RESULTS: A total of 224 patients received 244 continuous erector spinae catheters during the study period. After insertion of the erector spinae, there were no immediate complications such as hypotension, hypoxia, local anesthetic toxicity, or pneumothorax. Of all blocks inserted, 7.7% were removed due to catheter failure (8.4 per 100 catheters; 95% confidence interval [CI], 5.1-13.9 per 100 catheters). This resulted in a failure rate of 1.9 per 1000 catheter days (95% CI, 1.1-6.7 catheter days). Late complications included 2 erythematous catheter sites and 2 small hematomas not requiring intervention. The incidence of a minor late complication was 16.7 per 1000 catheters (95% CI, 6.1-45.5 per 1000 catheters). CONCLUSIONS: This study supports the statements made by regional anesthesia societies regarding the safety of the erector spinae plane block. Based on the results presented in this population of trauma patients, the erector spinae plane block catheter is a low-risk analgesic technique that may be performed in the presence of abnormal coagulation status or systemic infection.
引用
- White LD, Riley B, Davis K, et al. Safety of Continuous Erector Spinae Catheters in Chest Trauma: A Retrospective Cohort Study. Anesth Analg. 2021. PMID: 34473654. doi:10.1213/ANE.0000000000005730
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。