术前膝神经射频消融对全膝关节置换术后镇痛无效:一项预试验随机临床试验
结果显示,GN-RFA组在术后6周静息痛主要结局上较假手术组无显著改善,行走痛和身体功能等次要结局在各随访时间点也无显著差异。结论认为TKA术前对膝上外侧、膝上内侧和膝下内侧神经行常规GN-RFA未提供有临床意义的镇痛或功能改善。
要点
- TKA术前2至4周行常规GN-RFA未显著改善术后6周静息痛。
- 行走痛和身体功能等次要结局在各随访点组间均无显著差异。
- 该预试验不支持TKA术前常规使用GN-RFA镇痛。
核心结论
- TKA术前对膝上外侧、膝上内侧和膝下内侧神经行常规GN-RFA未提供有临床意义的镇痛或功能改善。
研究设计与样本
- 干预在TKA前2至4周进行,基线在干预当天术前测量,随访在手术当天术前及术后2周和6周进行。
主要发现
- 主要结局术后6周静息痛强度在GN-RFA组较假手术组无显著改善。
- 次要结局包括行走痛和身体功能在各随访评估中组间均无显著差异。
临床怎么用
- 基于该预试验结果,TKA术前常规GN-RFA不应被视为能改善术后镇痛或功能的措施。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Although total knee arthroplasty (TKA) is an effective treatment for severe knee osteoarthritis (OA), a subset of patients experience significant postoperative pain and dissatisfaction. Several clinical trials support the analgesic benefits of genicular nerve radiofrequency ablation (GN-RFA) for non-operative knee OA, but only one prior trial has examined the effects of this intervention given preoperatively on postoperative outcomes following TKA, showing no analgesic benefit of cooled GN-RFA. The current study evaluated whether conventional thermal GN-RFA performed preoperatively resulted in significant improvements in pain and function following TKA. METHODS: This was a single-center, prospective, randomized, sham-controlled, double-blinded pilot trial in which patients received either conventional GN-RFA (n=30) or sham (n=30) between 2 and 4 weeks prior to their TKA. Baseline measures were obtained preprocedurally on the day of intervention, with follow-up outcomes obtained preoperatively on the day of surgery, and at 2 and 6 weeks postoperatively. RESULTS: Patients receiving GN-RFA showed no significant improvements relative to sham controls in the primary outcome, pain intensity at rest at 6-week follow-up. Secondary outcomes, including pain with ambulation and physical function, also showed no significant differences between groups at any follow-up assessment. CONCLUSIONS: Conventional GN-RFA of the superior lateral, superior medial, and inferior medial genicular nerves when performed prior to TKA did not provide clinically significant pain relief or improvement in functional status at 2 or 6 weeks postoperatively. TRIAL REGISTRATION NUMBER: NCT02947321.
引用
- Mishra P, Edwards D, Huntoon M, et al. Is preoperative genicular radiofrequency ablation effective for reducing pain following total knee arthroplasty? A pilot randomized clinical trial. Reg Anesth Pain Med. 2021. PMID: 34215667. doi:10.1136/rapm-2021-102501
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。