全身麻醉中使用声门上气道装置后颞下颌关节功能障碍的前瞻性观察研究
该前瞻性观察研究纳入130例择期手术成人患者,以声门上气道装置作为主要气道工具,术前和术后分别采用12项问卷及客观测量(切牙间距、下颌前伸和侧向运动)评估颞下颌关节功能。主要结局切牙间距术前46.5(7.2)mm与术后46.3(7.5)mm无显著差异(p=0.521),差值0.2(95%CI -0.5至0.9)mm;张口时关节弹响报告率术后较术前降低(9.2% vs 21.5%,p<0.001),其他11项问卷回答及关节区疼痛无显著差异。结论认为声门上气道装置使用后未发现临床显著的颞下颌关节功能障碍。
要点
- 声门上气道装置使用后切牙间距无显著变化,差值0.2(95%CI -0.5至0.9)mm。
- 术后张口弹响报告率低于术前(9.2% vs 21.5%,p<0.001)。
- 颞下颌关节区疼痛及其他问卷条目术后无显著差异。
核心结论
- 基于问卷和客观测量,全身麻醉中使用声门上气道装置后未发现临床显著的颞下颌关节功能障碍。
研究设计与样本
- 前瞻性观察研究,纳入130例以声门上气道装置为主要气道工具的择期手术成人患者。
- 术前和术后采用改编自颞下颌关节量表和利物浦口腔康复问卷的12项问卷,并测量切牙间距、下颌前伸和侧向运动。
主要发现
- 平均(SD)切牙间距术前46.5(7.2)mm,术后46.3(7.5)mm,p=0.521,差值(95%CI)0.2(-0.5至0.9)mm。
- 平均(SD)下颌前伸术前3.6(2.4)mm,术后3.9(2.4)mm,p=0.018。
- 平均(SD)向右下颌侧向运动术前8.9(4.1)mm,术后9.1(4.0)mm,p=0.314。
- 平均(SD)向左下颌侧向运动术前8.8(4.0)mm,术后9.3(3.6)mm,p=0.008。
- 张口时报告关节弹响或爆裂声的患者术前28例(21.5%),术后12例(9.2%),p<0.001,差值(95%CI)12.3%(6.7-17.9%)。
关键数值与推荐
- 主要结局切牙间距术前与术后比较p=0.521,差值(95%CI)0.2(-0.5至0.9)mm。
- 下颌前伸运动术前与术后比较p=0.018。
- 向右下颌侧向运动术前与术后比较p=0.314。
- 向左下颌侧向运动术前与术后比较p=0.008。
- 张口时关节弹响报告率术前28例(21.5%)vs 术后12例(9.2%),p<0.001,差值(95%CI)12.3%(6.7-17.9%)。
临床怎么用
- 声门上气道装置用于全身麻醉时,现有证据未提示会导致临床显著的颞下颌关节功能障碍。
- 术后可关注患者张口弹响等颞下颌关节症状,但本研究显示弹响报告率术后低于术前。
局限性
- 原文未报告局限性相关内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Supraglottic airway devices are commonly used to manage the airway during general anaesthesia. There are sporadic case reports of temporomandibular joint dysfunction and dislocation following supraglottic airway device use. We conducted a prospective observational study of adult patients undergoing elective surgery where a supraglottic airway device was used as the primary airway device. Pre-operatively, all participants were asked to complete a questionnaire involving 12 points adapted from the Temporomandibular Joint Scale and the Liverpool Oral Rehabilitation Questionnaire. Objective measurements included inter-incisor distance as well as forward and lateral jaw movements. The primary outcome was the inter-incisor distance, an accepted measure of temporomandibular joint mobility. Both the questionnaire and measurements were repeated in the postoperative period and we analysed data from 130 participants. Mean (SD) inter-incisor distance in the pre- and postoperative period was 46.5 (7.2) mm and 46.3 (7.5) mm, respectively (p = 0.521) with a difference (95%CI) of 0.2 (-0.5 to 0.9) mm. Mean (SD) forward jaw movement in the pre- and postoperative period was 3.6 (2.4) mm and 3.9 (2.4) mm, respectively (p = 0.018). Mean (SD) lateral jaw movement to the right in the pre- and postoperative period was 8.9 (4.1) mm and 9.1 (4.0) mm, respectively (p = 0.314). Mean (SD) lateral jaw movement to the left in the pre- and postoperative period was 8.8 (4.0) mm and 9.3 (3.6) mm, respectively (p = 0.008). The number of patients who reported jaw clicks or pops before opening their mouth as wide as possible was 28 (21.5%) vs. 12 (9.2%) in the pre- and postoperative period, respectively (p < 0.001) with a difference (95%CI) of 12.3% (6.7-17.9%). There was no significant difference in the responses to the other 11 questions or in the number of patients who reported pain in the temporomandibular joint area postoperatively. No clinically significant dysfunction of the temporomandibular joint following the use of supraglottic airway devices in the postoperative period was identified by either patient questionnaires or objective measurements.