文献速递气道管理

成人清醒气管插管气道装置:系统综述与网状Meta分析

Airway devices for awake tracheal intubation in adults: a systematic review and network meta-analysis.
PubMed 文献 · Br J Anaesth · 2021-07-22

结果显示各装置首次插管成功率无差异,光导芯插管时间最短,柔性支气管镜最长。

要点

  • 光导芯、无槽视频喉镜和柔性支气管镜首次插管成功率无差异。
  • 光导芯插管时间最短,其次为无槽视频喉镜,柔性支气管镜最长。
  • 各装置在食管插管、氧饱和度下降等不良事件上无差异。

核心结论

  • 柔性支气管镜、光导芯、有槽和无槽视频喉镜在成人清醒气管插管中临床效果相当。
  • 光导芯插管时间最短,柔性支气管镜最长。

研究设计与样本

  • 系统综述与网状Meta分析,检索CENTRAL、CINAHL、EMBASE、MEDLINE和Web of Science。
  • 未评估直接喉镜。

主要发现

  • 首次插管成功率在各装置间无差异,证据质量因不精确性评为中等。
  • 光导芯插管时间最短,其次为无槽视频喉镜,柔性支气管镜最长,证据质量评为高。
  • 食管插管、更换气道技术、氧饱和度下降、气道出血、声嘶和咽痛发生率在各装置间无差异。

临床怎么用

  • 成人清醒气管插管可考虑光导芯或无槽视频喉镜以缩短插管时间。
  • 柔性支气管镜仍可作为可选装置,但插管时间可能较长。

局限性

  • 未纳入评估直接喉镜的RCT。
  • 首次插管成功率的证据质量因不精确性评为中等。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Awake tracheal intubation is commonly performed with flexible bronchoscopes, but the emerging role of alternative airway devices, such as videolaryngoscopes, direct laryngoscopes, and optical stylets, has been recognised. METHODS: CENTRAL, CINAHL, EMBASE, MEDLINE, and Web of Science were searched for RCTs that compared flexible bronchoscopes, direct laryngoscopes, optical stylets and channelled or unchannelled videolaryngoscopes in adult patients having awake tracheal intubation were included. The co-primary outcomes were first-pass success rate and time to tracheal intubation. Continuous outcomes were extracted as mean and standard deviation, and dichotomous outcomes were converted to overall numbers of incidence. Frequentist network meta-analysis was conducted, and network plots and network league tables were produced. RESULTS: Twelve RCTs were included, none of which evaluated direct laryngoscopes. The first-pass success rate was not different between flexible bronchoscopes, optical stylets, and channelled and unchannelled videolaryngoscopes, with the quality of evidence rated as moderate in view of imprecision. Optical stylets, followed by unchannelled videolaryngoscopes and then felxible bronchoscopes resulted in the shortest time to tracheal intubation, with the quality of evidence rated as high. No differences were shown between the airway devices with respect to the incidence of oesophageal intubation, change of airway technique, oxygen desaturation, airway bleeding, or the rate of hoarseness and sore throat. CONCLUSIONS: Flexible bronchoscopes, optical stylets, and channelled and unchannelled videolaryngoscopes were clinically comparable airway devices in the setting of awake trachela intubation and the time to tracheal intubation was shortest with optical stylets and longest with flexible bronchoscopes.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Desai N, Ratnayake G, Onwochei DN, et al. Airway devices for awake tracheal intubation in adults: a systematic review and network meta-analysis. Br J Anaesth. 2021. PMID: 34303493. doi:10.1016/j.bja.2021.05.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。