生理盐水与空气充盈套囊对小儿MicroCuff®气管导管高套囊内压发生率的影响:随机对照试验
这项单中心前瞻性随机对照试验纳入48例年龄4个月至16岁的小儿,比较生理盐水与空气充盈气管导管套囊对术中套囊内压过高的影响。生理盐水组需降低套囊内压的患者为1/24,空气组为16/24(p < 0.001),拔管相关不良事件两组相似(15/24 vs. 13/24;p = 0.770)。生理盐水充盈套囊可减少小儿麻醉中高套囊内压的发生。
要点
- 生理盐水充盈小儿气管导管套囊可显著减少术中套囊内压过高。
- 空气充盈组多数患儿需术中降低套囊内压,生理盐水组极少。
- 两组拔管相关不良呼吸事件发生率无显著差异。
核心结论
- 使用生理盐水充盈小儿带套囊气管导管套囊可降低麻醉期间高套囊内压的发生率。
研究设计与样本
- 单中心、前瞻性、随机对照试验,纳入48例年龄≤16岁(4个月至16岁)的患儿,每组24例,分别用生理盐水或空气充盈套囊。
主要发现
- 需降低套囊内压的患者在生理盐水组为1/24,空气组为16/24(p < 0.001)。
- 拔管相关不良事件发生率生理盐水组15/24,空气组13/24(p = 0.770)。
关键数值与推荐
- 术中测量套囊内压,若超过安全上限25 cmH2O则降至初始充盈水平。
临床怎么用
- 小儿使用带套囊气管导管且术中应用氧化亚氮时,可考虑用生理盐水而非空气充盈套囊,以减少套囊内压过高。
局限性
- 单中心研究,样本量较小(48例),年龄跨度大(4个月至16岁)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The use of cuffed tracheal tubes in paediatric anaesthesia is now common. The use of nitrous oxide in anaesthesia risks excessive tracheal tube cuff pressures, as nitrous oxide can diffuse into the cuff during the course of surgery. The aim of this single-centre, prospective, randomised controlled trial was to compare the effect of saline versus air for the inflation of tracheal tube cuffs on the incidence of excessive intra-operative cuff pressure in children undergoing balanced anaesthesia with nitrous oxide. Children (age ≤ 16 y) were randomly allocated to receive either saline (saline group) or air (air group) to inflate the cuff of their tracheal tube. The pressure in the tracheal tube cuff was measured during surgery and brought down to the initial inflation level if it breached a safe limit (25 cmH2 O). Post-extubation adverse respiratory events were noted. Data from 48 patients (24 in each group), aged 4 months to 16 y, were analysed. The requirement for reduction in intra-cuff pressure occurred in 1/24 patients in the saline group, compared with 16/24 patients in the air group (p < 0.001). The incidence of extubation-related adverse events was similar in the saline and air groups (15/24 vs. 13/24, respectively; p = 0.770). The use of saline to inflate the cuff of paediatric cuffed tubes reduces the incidence of high intra-cuff pressures during anaesthesia. This may provide a pragmatic extra safety barrier to help reduce the incidence of excessive tracheal cuff pressure when nitrous oxide is used during paediatric anaesthesia.
引用
- Armstrong J, Jenner P, Poulose S, et al. The effect of saline versus air for cuff inflation on the incidence of high intra-cuff pressure in paediatric MicroCuff® tracheal tubes: a randomised controlled trial. Anaesthesia. 2021. PMID: 33891328. doi:10.1111/anae.15493
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。