文献速递气道管理术前评估与围术期医学

高流量鼻氧治疗与传统面罩通气后胃内气体体积的CT比较

A comparison of gastric gas volumes measured by computed tomography after high-flow nasal oxygen therapy or conventional facemask ventilation.
PubMed 文献 · Anaesthesia · 2021-03-02

本研究比较了围插管期高流量鼻氧治疗与传统面罩预氧合通气后胃内气体体积。两组各50例成人肝肿瘤经皮热消融全麻插管患者,插管后立即CT测量胃内气体体积。高流量鼻氧组中位胃气体积24.0 cm³,面罩组23.8 cm³,两组无差异(Mann-Whitney U检验,U=1136,p=0.432,n1=n2=50)。

要点

  • 围插管期高流量鼻氧不增加胃内气体体积。
  • 麻醉诱导后胃内少量积气常见。
  • 高流量鼻氧可用于误吸风险较高患者的围插管期氧合。

核心结论

  • 围插管期高流量鼻氧治疗用于预氧合和呼吸暂停期间,与常规面罩预氧合通气相比,不增加CT测量的胃内气体体积。

研究设计与样本

  • 回顾性比较两组各50例成人肝肿瘤经皮热消融全麻插管患者,一组接受围插管期高流量鼻氧治疗,另一组接受常规面罩预氧合通气。

主要发现

  • 高流量鼻氧组胃内气体体积中位数(IQR[范围])为24.0(14.2-59.9[3-167])cm³。
  • 面罩组胃内气体体积中位数(IQR[范围])为23.8(12.6-38.8[0-185])cm³。
  • 两组胃内气体体积无差异(Mann-Whitney U检验,U=1136,p=0.432,n1=n2=50)。

临床怎么用

  • 围插管期高流量鼻氧治疗不增加胃内气体体积,可考虑用于误吸风险较高患者的预氧合和呼吸暂停期间氧合。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

High-flow nasal oxygen therapy is increasingly used to improve peri-intubation oxygenation. However, it is unknown whether it may cause or exacerbate insufflation of gas into the stomach. High-flow nasal oxygen therapy is now standard practice in our hospital for adult patients undergoing percutaneous thermal ablation of liver cancer under general anaesthesia with tracheal intubation. We compared gastric gas volumes measured from computed tomography images that had been acquired immediately after intubation in two series of patients: 50 received peri-intubation high-flow nasal oxygen therapy and another 50 received conventional facemask pre-oxygenation and ventilation before intubation and before high-flow nasal oxygen therapy became standard practice in our unit. Median (IQR [range]) gastric gas volume was 24.0 (14.2-59.9 [3-167]) cm3 in the high-flow nasal oxygen therapy group and 23.8 (12.6-38.8 [0-185]) cm3 in the facemask group. There was no difference between the two groups in the volume of gastric gas measured by computed tomography imaging (Mann-Whitney U-test, U = 1136, p = 0.432, n1 = n2 = 50). Our results demonstrate that a small volume of gastric gas is commonly present after induction of anaesthesia, but that the use of peri-intubation high-flow nasal oxygen therapy for pre-oxygenation and during apnoea does not increase this volume compared with conventional facemask pre-oxygenation and ventilation. This is clinically relevant, as high-flow nasal oxygen therapy is increasingly being used in a peri-intubation context and in patients at higher risk of aspiration.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Sud A, Athanassoglou V, Anderson EM, et al. A comparison of gastric gas volumes measured by computed tomography after high-flow nasal oxygen therapy or conventional facemask ventilation. Anaesthesia. 2021. PMID: 33651914. doi:10.1111/anae.15433

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。