文献速递气道管理术前评估与围术期医学

颈椎固定患者气管插管装置效果:系统综述与网状Meta分析

Effectiveness of intubation devices in patients with cervical spine immobilisation: a systematic review and network meta-analysis.
PubMed 文献 · Br J Anaesth · 2021-02-17

该系统综述与网状Meta分析纳入80项随机试验共8039例成人颈椎固定患者,比较26种插管装置。以Macintosh直接喉镜为参照,McGrath、C-MAC D Blade、Airtraq、King Vision、C-MAC及配合管芯的GlideScope首次插管成功率更高;仅Airway Scope在MILS下优于Macintosh。

要点

  • 颈椎固定患者中,McGrath等7种装置首次插管成功率优于Macintosh直接喉镜。
  • MILS固定时仅Airway Scope显示优于Macintosh,证据有限。
  • 需更多采用MILS而非颈托的研究以贴近临床实践。

核心结论

  • 颈椎固定患者插管时,7种装置首次插管成功率优于Macintosh直接喉镜。
  • 需更多使用MILS而非颈托等替代方法的研究以更准确反映临床实践。

研究设计与样本

  • 系统综述与随机效应网状Meta分析,检索MEDLINE、EMBASE和Cochrane Library。
  • 纳入80项随机试验共8039例成人颈椎固定患者,比较26种插管装置。
  • 主要结局为首次插管成功概率,以Macintosh直接喉镜为参照装置。

主要发现

  • 与Macintosh相比,McGrath首次插管成功OR=11.5(95%CrI 3.19-46.20)。
  • C-MAC D Blade OR=7.44(95%CrI 1.06-52.50),Airtraq OR=5.43(95%CrI 2.15-14.2)。
  • King Vision OR=4.54(95%CrI 1.28-16.30),C-MAC OR=4.20(95%CrI 1.28-15.10)。
  • 配合管芯的GlideScope OR=3.54(95%CrI 1.05-12.50)。
  • MILS固定时仅Airway Scope优于Macintosh,OR=7.98(95%CrI 1.06-73.00)。

临床怎么用

  • 颈椎固定患者插管可优先考虑McGrath、C-MAC D Blade、Airtraq、King Vision、C-MAC或配合管芯的GlideScope以提高首次成功率。
  • 采用MILS固定时,Airway Scope可作为优于Macintosh的选择。

局限性

  • MILS相关研究较少,多数证据来自颈托或其他替代固定方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cervical spine immobilisation increases the difficulty of tracheal intubation. Many intubation devices have been evaluated in this setting, but their relative performance remains uncertain. METHODS: MEDLINE, EMBASE, and the Cochrane Library were searched to identify randomised trials comparing two or more intubation devices in adults with cervical spine immobilisation. After critical appraisal, a random-effects network meta-analysis was used to pool and compare device performance. The primary outcome was the probability of first-attempt intubation success (first-pass success). For relative performance, the Macintosh direct laryngoscopy blade was chosen as the reference device. RESULTS: We included 80 trials (8039 subjects) comparing 26 devices. Compared with the Macintosh, McGrath™ (odds ratio [OR]=11.5; 95% credible interval [CrI] 3.19-46.20), C-MAC D Blade™ (OR=7.44; 95% CrI, 1.06-52.50), Airtraq™ (OR=5.43; 95% CrI, 2.15-14.2), King Vision™ (OR=4.54; 95% CrI, 1.28-16.30), and C-MAC™ (OR=4.20; 95% CrI=1.28-15.10) had a greater probability of first-pass success. This was also true for the GlideScope™ when a tube guide was used (OR=3.54; 95% CrI, 1.05-12.50). Only the Airway Scope™ had a better probability of first-pass success compared with the Macintosh when manual-in-line stabilisation (MILS) was used as the immobilisation technique (OR=7.98; 95% CrI, 1.06-73.00). CONCLUSIONS: For intubation performed with cervical immobilisation, seven devices had a better probability of first-pass success compared with the Macintosh. However, more studies using MILS (rather than a cervical collar or other alternative) are needed, which more accurately represent clinical practice. CLINICAL TRIAL REGISTRATION: PROSPERO 2019 CRD42019158067 (https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=158067).

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Singleton BN, Morris FK, Yet B, et al. Effectiveness of intubation devices in patients with cervical spine immobilisation: a systematic review and network meta-analysis. Br J Anaesth. 2021. PMID: 33610262. doi:10.1016/j.bja.2020.12.041