体位对肥胖患者麻醉后面罩通气效果的影响:随机交叉研究
结果显示25°半坐位下呼出潮气量和呼吸分钟通气量均高于仰卧位,提示半坐位可改善麻醉肌松后肥胖患者的面罩通气。
要点
- 肥胖患者麻醉肌松后,25°半坐位面罩通气优于仰卧位。
- 25°半坐位呼出潮气量9.3±2.7 vs 仰卧位7.6±2.4 ml kg-1(P<0.001)。
- 25°半坐位呼吸分钟通气量139.6±40.7 vs 仰卧位113.4±35.7 ml kg-1 min-1(P<0.001)。
核心结论
- 在麻醉肌松的肥胖患者中,25°半坐位较仰卧位改善面罩通气效果。
主要发现
- 25°半坐位呼出潮气量为9.3±2.7 ml kg-1,高于仰卧位的7.6±2.4 ml kg-1(P<0.001)。
- 25°半坐位呼吸分钟通气量为139.6±40.7 ml kg-1 min-1,高于仰卧位的113.4±35.7 ml kg-1 min-1(P<0.001)。
关键数值与推荐
- 通气采用压力控制模式,峰吸气压力15 cmH2O,呼吸频率15 bpm,不加呼气末正压。
- 通气结局按瘦体重计算,通气不足定义为呼出潮气量小于4 ml kg-1或无法记录到呼气末CO2。
临床怎么用
- 对麻醉肌松的肥胖患者行面罩通气时,可考虑采用25°半坐位以改善通气效果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Airway management is more challenging in the obese. Compared with the supine position, the sitting position can decrease the collapsibility of the upper airway and improve respiratory mechanics. OBJECTIVE: The aim of this study was to evaluate the 25° semisitting position on the effectiveness of mask ventilation in anaesthetised paralysed obese patients. DESIGN: A randomised, cross-over study. SETTING: Medical centre managed by a university tertiary hospital. PATIENTS: Thirty-eight obese adults scheduled for general anaesthesia. METHODS: After anaesthesia and paralysis, two-handed mask ventilation was performed in the supine and 25° semi-sitting positions with a cross-over, in a randomised order. During mask ventilation, mechanical ventilation was delivered with a pressure-controlled mode with a peak inspiratory pressure of 15 cmH2O, a respiratory rate of 15 bpm, and no positive end-expiratory pressure. Ventilatory outcomes were based upon lean body weight. MAIN OUTCOMES: Exhaled tidal volume (ml kg-1), respiratory minute volume (ml kg-1 min-1), and the occurrence of inadequate ventilation, defined as an exhaled tidal volume less than 4 ml kg-1, or absence of end-tidal CO2 recording. RESULTS: Exhaled tidal volume (mean ± SD) in the 25° semi-sitting position was higher than in the supine position, 9.3 ± 2.7 vs. 7.6 ± 2.4 ml kg-1; P less than 0.001. Respiratory minute volume was improved in the 25° semisitting position compared with that in the supine position, 139.6 ± 40.7 vs. 113.4 ± 35.7 ml kg-1 min-1; P less than 0.001. CONCLUSION: The 25° semisitting position improved mask ventilation compared with the supine position in anaesthetised paralysed obese patients. TRIAL REGISTRY NUMBER: ClinicalTrials.gov (NCT03996161).
引用
- Chang JE, Seol T, Hwang JY, et al. Body position and the effectiveness of mask ventilation in anaesthetised paralysed obese patients: A randomised cross-over study. Eur J Anaesthesiol. 2021. PMID: 33600105. doi:10.1097/EJA.0000000000001473
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。