分娩硬膜外镇痛产妇器械阴道分娩风险相关因素:回顾性队列研究
该回顾性队列研究纳入2012至2015年新加坡某大型公立产科机构17 227例接受分娩硬膜外镇痛的阴道分娩产妇,器械分娩发生率为12%(n=2069)。多因素分析发现初产、高龄、较矮身高、使用前列腺素、较长第二产程、较高出生体重、突破性疼痛、较密运动阻滞及宫口开全时停止硬膜外输注等因素与器械分娩风险独立相关。
要点
- 初产使器械分娩风险显著增加(aOR 2.97),高龄亦为独立危险因素。
- 突破性疼痛(aOR 1.55)和较密运动阻滞(aOR 1.14)增加器械分娩风险。
- 宫口开全时停止硬膜外输注与器械分娩风险升高相关(aOR 1.18)。
核心结论
- 多因素模型有助于识别器械分娩高风险产妇,以便干预可改变因素并改善临床管理。
研究设计与样本
- 回顾性队列数据研究,纳入2012年1月至2015年12月新加坡某大型公立产科机构所有接受分娩硬膜外镇痛的阴道分娩产妇,共17 227例。
主要发现
- 17 227例接受分娩硬膜外镇痛的产妇中,12%(n=2069)发生器械分娩。
- 初产(aOR 2.97,95% CI 2.61–3.39,P<0.0001)和高龄(aOR 1.04,95% CI 1.03–1.05,P<0.0001)与器械分娩风险升高独立相关。
- 较高身高与器械分娩风险降低相关(aOR 0.18,95% CI 0.08–0.40,P<0.0001)。
- 使用前列腺素(aOR 1.19,95% CI 1.07–1.32,P=0.0014)、硬膜外镇痛前用药(aOR 1.16,95% CI 1.05–1.28,P=0.0040)、较长第二产程(aOR 1.23,95% CI 1.20–1.26,P<0.0001)、较高出生体重(aOR 1.27,95% CI 1.12–1.43,P=0.0002)及由资深麻醉医师实施硬膜外(aOR 1.94,95% CI 1.72–2.18,P<0.0001)与器械分娩风险升高相关。
- 突破性疼痛(aOR 1.55,95% CI 1.37–1.76,P<0.0001)、较密运动阻滞(aOR 1.14,95% CI 1.03–1.25,P=0.0097)及宫口开全时停止硬膜外输注(aOR 1.18,95% CI 1.05–1.32,P=0.0048)与器械分娩风险升高相关,模型ROC=0.75。
临床怎么用
- 可利用多因素模型识别器械分娩高风险产妇,针对可改变因素(如突破性疼痛、运动阻滞程度、宫口开全时是否停泵)优化管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Epidural analgesia is the most effective form of labour analgesia, but is associated with an increased risk of instrumental delivery. OBJECTIVE: To evaluate factors that are associated with an increased risk of instrumental delivery. DESIGN: Retrospective cohort data study. SETTING: Singapore's major public maternity institution. PATIENTS: All obstetric patients who received labour epidural analgesia for vaginal delivery between January 2012 to December 2015. INTERVENTION: None. MAIN OUTCOME MEASURES: Our primary outcome was the incidence of instrumental delivery. RESULTS: Out of 17 227 pregnant women who received labour epidural analgesia, 12% (n = 2069) had instrumental delivery. Independent factors associated with an increased risk of instrumental delivery included maternal factors [nulliparity (adjusted odds ratio (aOR) 2.97, 95% CI 2.61 to 3.39, P < 0.0001] and advanced maternal age (aOR 1.04, 95% CI 1.03 to 1.05, P < 0.0001)). Greater maternal height (aOR 0.18, 95% CI 0.08 to 0.40), P < 0.0001) was associated with a reduced risk of instrumental delivery. Significant labour-related factors increasing the risk of an instrumental delivery were the use of prostin (aOR 1.19, 95% CI 1.07 to 1.32, P = 0.0014), pre-epidural analgesia (aOR 1.16, 95% CI 1.05 to 1.28, P = 0.0040), a longer second stage of labour (aOR 1.23, 95% CI 1.20 to 1.26, P < 0.0001), higher infant birth weight (aOR 1.27, 95% CI 1.12 to 1.43, P = 0.0002) and an epidural performed by a senior anaesthetist (aOR 1.94, 95% CI 1.72 to 2.18, P < 0.0001). Labour epidural-related factors for an increased risk of instrumental delivery were the occurrence of breakthrough pain (aOR 1.55, 95% CI 1.37 to 1.76, P < 0.0001), a more dense motor block (aOR 1.14, 95% CI 1.03 to 1.25, P = 0.0097) and having an epidural infusion stopped at full cervical dilatation (aOR 1.18, 95% CI 1.05 to 1.32, P = 0.0048) [receiver operating characteristic (ROC) = 0.75]. CONCLUSIONS: The multivariate model generated would help identify women at higher risk of instrumental delivery, which can help clinicians to address potentially modifiable factors and improve clinical care.
引用
- Au-Yong PS, Tan CW, Tan WH, et al. Factors associated with an increased risk of instrumental vaginal delivery in women with epidural analgesia for labour: A retrospective cohort study. Eur J Anaesthesiol. 2021. PMID: 33443381. doi:10.1097/EJA.0000000000001439
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。