文献速递疼痛医学区域麻醉与超声

超声引导膝神经射频消融新方案:解剖靶点准确性尸体研究验证

Validation of a new protocol for ultrasound-guided genicular nerve radiofrequency ablation with accurate anatomical targets: cadaveric study.
PubMed 文献 · Reg Anesth Pain Med · 2020-12-03

结果显示5条目标神经均被准确捕获,理论最大单极射频灶捕获比例除SLGN为95%外其余均为100%,预期可改善临床结局。

要点

  • 修订解剖标志的超声引导膝神经射频消融可准确捕获5条目标神经
  • 理论最大单极射频灶对SMGN、IMGN、RFN及IPBSN捕获比例为100%,SLGN为95%
  • 新方案扩大感觉去神经支配的神经范围,预期改善临床结局

核心结论

  • 采用修订解剖靶点的超声引导膝神经射频消融能准确捕获5条目标神经,预期可改善临床结局。

主要发现

  • 黑标直接接触神经的比例:SMGN为7/10、SLGN为8/10、IMGN为10/10、RFN为9/10。
  • 理论最大单极射频灶捕获神经比例:SMGN、IMGN、RFN及IPBSN均为100%,SLGN为95%。
  • 黑标中心到目标神经的平均距离:SMGN为2.1±2.2 mm、SLGN为1.0±1.4 mm、IMGN为0.75±1.1 mm、RFN为2.4±4.5 mm。

关键数值与推荐

  • 靶点包括膝上内侧神经(SMGN)、膝上外侧神经(SLGN)、膝下内侧神经(IMGN)、腓返神经(RFN)及隐神经髌下支(IPBSN)。

临床怎么用

  • 临床可参照修订解剖标志行超声引导膝神经射频消融,以更精确地实现多神经感觉去神经支配。

局限性

  • 研究为尸体模型,样本量有限(预实验4膝、正式实验10膝),临床结局尚未评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Ultrasound (US)-guided radiofrequency ablation (RFA) of genicular nerves (GNs) is increasingly performed to manage chronic knee pain. The anatomical foundations supporting the choice of original targets for US-guided GN-RFA have been thoroughly improved by recent anatomical studies. Therefore, this study aimed to provide a new protocol with revised anatomical targets for US-guided GN-RFA and to assess their accuracy in a cadaveric model. MATERIALS AND METHODS: Fourteen fresh-frozen cadaveric knees were used. After a pilot study with 4 knees, five consistent nerves were targeted in the other 10 knees with revised anatomical landmarks: superior medial genicular nerve (SMGN), superior lateral genicular nerve (SLGN), inferior medial genicular nerve (IMGN), recurrent fibular nerve (RFN) and the infrapatellar branch of the saphenous nerve (IPBSN). For each nerve, the lumen of radiofrequency (RF) cannula was prefilled with non-diffusible black paint, and then the cannula was inserted at the target site under US guidance. After US verification of correct placement, the stylet was introduced in the cannula to create a limited black mark on the tissues at the top of the active tip. Anatomical dissection was performed to assess for accuracy. RESULTS: The proportion of nerves directly found in contact with the black mark was 7/10, 8/10, 10/10 and 9/10 for the SMGN, SLGN, IMGN and RFN, respectively. The proportions of nerve captured by the theoretical largest monopolar RF lesions were 100% for the SMGN, IMGN and RFN, and IPBSN and 95% for SLGN. The mean distances from the center of the black mark to the targeted nerve were 2.1±2.2 mm, 1.0±1.4 mm, 0.75±1.1 mm and 2.4±4.5 mm for the SMGN, SLGN, IMGN and RFN, respectively. CONCLUSION: US-guided GN-RFA with revised anatomical targets resulted in accurate capture of the five targeted nerves. This protocol provides precise sensory denervation of a larger panel of nerves, targeting those whose constancy regarding anatomical location has been clearly demonstrated. It is expected to improve the clinical outcomes.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Fonkoue L, Stoenoiu MS, Behets CW, et al. Validation of a new protocol for ultrasound-guided genicular nerve radiofrequency ablation with accurate anatomical targets: cadaveric study. Reg Anesth Pain Med. 2020. PMID: 33273065. doi:10.1136/rapm-2020-101936

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。