文献速递小儿麻醉气道管理

经鼻湿化快速充气通气交换对无呼吸小儿的通气效应:两种氧流量随机对照试验

Evaluating the ventilatory effect of transnasal humidified rapid insufflation ventilatory exchange in apnoeic small children with two different oxygen flow rates: a randomised controlled trial.
PubMed 文献 · Anaesthesia · 2020-12-22

本研究为非劣效性随机对照试验,纳入体重10-15 kg无呼吸小儿,比较经鼻湿化快速充气通气交换(THRIVE)在2与4 l.kg-1.min-1氧流量下10分钟无呼吸期内的二氧化碳清除效果。结果显示两组经皮二氧化碳上升速率均为0.46 kPa.min-1,2 l.kg-1.min-1组非劣效于4 l.kg-1.min-1组,且两种流量下均未见额外通气效应。

要点

  • 2 l.kg-1.min-1与4 l.kg-1.min-1氧流量下经皮二氧化碳上升速率相同,均为0.46 kPa.min-1。
  • 2 l.kg-1.min-1氧流量非劣效于4 l.kg-1.min-1,单侧95%CI上限0.07 kPa.min-1低于预设非劣效界值0.147 kPa.min-1(p=0.001)。
  • 10-15 kg无呼吸小儿中,THRIVE在2或4 l.kg-1.min-1流量下均未见额外通气效应。

核心结论

  • 在体重10-15 kg无呼吸小儿中,THRIVE在2或4 l.kg-1.min-1氧流量下均未见额外通气效应。
  • 2 l.kg-1.min-1氧流量相对于4 l.kg-1.min-1在经皮二氧化碳上升速率上为非劣效。

研究设计与样本

  • 非劣效性随机对照试验,比较两种高流量鼻疗氧流量在10分钟无呼吸期内的二氧化碳清除效果。
  • 纳入体重10-15 kg的小儿,每组15例,随机分配至2或4 l.kg-1.min-1氧流量组。
  • 标准化麻醉诱导包括神经肌肉阻滞,持续托下颌确保气道通畅。

主要发现

  • 2 l.kg-1.min-1组经皮二氧化碳平均(SD)上升速率为0.46(0.11)kPa.min-1。
  • 4 l.kg-1.min-1组经皮二氧化碳平均(SD)上升速率为0.46(0.12)kPa.min-1。
  • 组间差异单侧95%CI上限为0.07 kPa.min-1,低于预设非劣效界值0.147 kPa.min-1(p=0.001)。

关键数值与推荐

  • 非劣效界值预设为0.147 kPa.min-1。
  • 研究干预因安全原因终止标准:SpO2降至<95%、经皮二氧化碳升至>9.3 kPa、近红外光谱值较基线下降>20%,或无呼吸期达10分钟。

临床怎么用

  • 对于体重10-15 kg无呼吸小儿,THRIVE在2或4 l.kg-1.min-1氧流量下均不能提供额外通气效应,临床应关注二氧化碳蓄积风险。
  • 较低氧流量2 l.kg-1.min-1在二氧化碳清除方面不劣于4 l.kg-1.min-1,可考虑使用较低流量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Transnasal humidified rapid insufflation ventilatory exchange prolongs safe apnoeic oxygenation time in children. In adults, transnasal humidified rapid insufflation ventilatory exchange is reported to have a ventilatory effect with PaCO2 levels increasing less rapidly than without it. This ventilatory effect has yet to be reproduced in children. In this non-inferiority study, we tested the hypothesis that children weighing 10-15 kg exhibit no difference in carbon dioxide clearance when comparing two different high-flow nasal therapy flow rates during a 10-min apnoea period. Following standardised induction of anaesthesia including neuromuscular blockade, patients were randomly allocated to high-flow nasal therapy of 100% oxygen at 2 or 4 l.kg-1 .min-1 . Airway patency was ensured by continuous jaw thrust. The study intervention was terminated for safety reasons when SpO2 values dropped < 95%, or transcutaneous carbon dioxide levels rose > 9.3 kPa, or near-infrared spectroscopy values dropped > 20% from their baseline values, or after an apnoeic period of 10 min. Fifteen patients were included in each group. In the 2 l.kg-1 .min-1 group, mean (SD) transcutaneous carbon dioxide increase was 0.46 (0.11) kPa.min-1 , while in the 4 l.kg-1 .min-1 group it was 0.46 (0.12) kPa.min-1 . The upper limit of a one-sided 95%CI for the difference between groups was 0.07 kPa.min-1 , lower than the predefined non-inferiority margin of 0.147 kPa.min-1 (p = 0.001). The lower flow rate of 2 l.kg-1 .min-1 was non-inferior to 4 l.kg-1 .min-1 relative to the transcutaneous carbon dioxide increase. In conclusion, an additional ventilatory effect of either 2 or 4 l.kg-1 .min-1 high-flow nasal therapy in apnoeic children weighing 10-15 kg appears to be absent.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Riva T, Préel N, Theiler L, et al. Evaluating the ventilatory effect of transnasal humidified rapid insufflation ventilatory exchange in apnoeic small children with two different oxygen flow rates: a randomised controlled trial. Anaesthesia. 2020. PMID: 33351194. doi:10.1111/anae.15335

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。