文献速递产科麻醉区域麻醉与超声

超声提高腰硬联合麻醉中经硬膜外针放置腰麻针的成功率:一项随机对照研究

Ultrasound increases the success rate of spinal needle placement through the epidural needle during combined spinal-epidural anaesthesia: A randomised controlled study.
PubMed 文献 · Eur J Anaesthesiol · 2021-01-01

该前瞻性随机双盲研究纳入185例择期剖宫产产妇,比较术前超声扫描定位与常规触诊定位对腰硬联合麻醉中经硬膜外针放置腰麻针首次尝试成功率的影响。结果显示超声组首次尝试成功率显著高于触诊组(93.8% vs 68.8%,P<0.001),并缩短了总操作时间和腰麻针放置时间,减少了硬膜外针重新定向的患者数。

要点

  • 术前超声定位可提高经硬膜外针放置腰麻针的首次尝试成功率。
  • 超声定位缩短腰硬联合麻醉总操作时间及腰麻针放置时间。
  • 超声定位减少腰麻针放置过程中硬膜外针重新定向的需要。

核心结论

  • 对于经验丰富的麻醉医师,术前超声成像可显著提高剖宫产产妇在腰硬联合麻醉下经硬膜外针放置腰麻针的首次尝试成功率。

研究设计与样本

  • 前瞻性、随机、双盲研究,单中心,2019年6月至9月于中国医科大学附属盛京医院麻醉科进行。
  • 共纳入185例择期剖宫产产妇,年龄24至52岁,ASA II-III级,孕38至40周,随机分为超声组和触诊组。

主要发现

  • 超声组首次尝试成功率93.8%,触诊组68.8%,差异有统计学意义(P<0.001)。
  • 超声组腰硬联合麻醉总操作时间186.9 ± 37.1秒,触诊组213 ± 60.4秒(P=0.0015)。
  • 超声组腰麻针成功放置时间78.3 ± 22.9秒,触诊组100.1 ± 53.7秒(P<0.01)。
  • 超声组4例患者需要硬膜外针重新定向,触诊组20例(P<0.01)。

临床怎么用

  • 在剖宫产腰硬联合麻醉中,可考虑术前使用超声扫描定位穿刺点以提高腰麻针放置成功率并缩短操作时间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Combined spinal-epidural anaesthesia (CSEA) using a needle-through-needle technique is currently widely used. However, successful epidural needle placement does not mean a successful spinal needle placement during CSEA. Whether ultrasound assistance could increase the first-pass success rate of spinal needle placement for CSEA remains unknown. OBJECTIVE: The aim of this study was to investigate if ultrasound assistance could increase the first-pass success rate of spinal needle placement through the epidural needle during CSEA performed by experienced anaesthesiologists in patients undergoing caesarean section. DESIGN: A prospective, randomised, double-blind study. SETTING: Single centre, Department of Anaesthesiology, Shengjing Hospital, China Medical University, China, from June 2019 to September 2019. PATIENTS: A total of 185 patients (aged 24 years to 52 years, American Society of Anesthesiologists grade (ASA) II-III, 38 to 40 weeks gestation) scheduled to undergo elective caesarean section under CSEA were enrolled. INTERVENTION: The patients were randomised to either an ultrasound group (patients received a preprocedural ultrasound scan, and the puncture site was identified by ultrasound imaging) and a palpation group (patients received a sham procedural ultrasound scan, and the puncture site was identified by conventional palpation). MAIN OUTCOME MEASURES: The primary outcome measure was the first-pass success rate for spinal needle placement through the epidural needle. Secondary outcome measures were total duration of CSEA, time required for successful epidural needle and spinal needle placement, number of epidural needle redirections and complications. RESULTS: Preprocedural ultrasound imaging significantly increased the first-pass success rate of spinal needle placement through the epidural needle compared with conventional palpation (93.8 vs. 68.8%, P < 0.001). Preprocedural ultrasound imaging also decreased the total duration of CSEA (186.9 ± 37.1 vs. 213 ± 60.4 s, P = 0.0015) and the time required for successful spinal needle placement (78.3 ± 22.9 vs. 100.1 ± 53.7 s, P < 0.01) compared with conventional palpation. Fewer patients in the ultrasound group needed epidural needle redirections during the spinal needle placement procedure than in the palpation group (four patients vs. 20 patients, P < 0.01). CONCLUSION: For experienced anaesthesiologists, preprocedural ultrasound imaging significantly increased the first-pass success rate of spinal needle placement through the epidural needle for obstetric patients undergoing caesarean section under CSEA. TRIAL REGISTRATION: chictr.org.cn, identifier: ChiCTR1900024132.

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Tao B, Liu K, Ding M, et al. Ultrasound increases the success rate of spinal needle placement through the epidural needle during combined spinal-epidural anaesthesia: A randomised controlled study. Eur J Anaesthesiol. 2021. PMID: 33122574. doi:10.1097/EJA.0000000000001380

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。