20%七氟烷乳剂静脉输注在犬中的麻醉效力及对血气分配系数的影响
本研究在6只犬中采用随机交叉设计,比较20%七氟烷乳剂静脉麻醉与七氟烷吸入麻醉。
要点
- 20%七氟烷乳剂静脉麻醉未显著增加犬的血气分配系数。
- 乳剂静脉麻醉的MAC低于吸入麻醉,提示麻醉效力可能相当或更强。
- 乳剂静脉麻醉诱导和苏醒更迅速,安全性良好。
核心结论
- 20%七氟烷乳剂静脉麻醉与吸入麻醉相比未显著增加血气分配系数。
- 该乳剂的麻醉效力可能等于或高于七氟烷吸入麻醉。
研究设计与样本
- 在6只犬中进行的随机交叉子研究,比较乳剂静脉麻醉与七氟烷吸入麻醉。
- 采用序贯法通过甩尾刺激测定最低肺泡浓度(MAC),气相色谱法测定血中七氟烷浓度和分压。
主要发现
- 乳剂静脉麻醉的诱导和苏醒比吸入麻醉更迅速。
- 乳剂静脉麻醉期间可通过气体监测仪估算呼气末七氟烷浓度。
- 未观察到严重并发症。
临床怎么用
- 20%七氟烷乳剂静脉麻醉可作为犬麻醉的可行选择,诱导苏醒快且不显著改变血气分配系数。
局限性
- 研究仅纳入6只犬,样本量小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intravenous (IV) infusions of volatile anesthetics in lipid emulsion may increase blood lipid concentration, potentially altering the anesthetic agent's blood solubility and blood-gas partition coefficient (BGPC). We examined the influence of a low-lipid concentration 20% sevoflurane emulsion on BGPC, and the anesthetic potency of this emulsion using dogs. METHODS: We compared BGPC and anesthetic characteristics in 6 dogs between the IV anesthesia of emulsion and the sevoflurane inhalation anesthesia in a randomized crossover substudy. Minimum alveolar concentrations (MACs) were determined by tail-clamp stimulation by using the up-and-down method. Blood sevoflurane concentration and partial pressure were measured by gas chromatography; end-tidal sevoflurane concentration was measured using a gas monitor. The primary outcome was BGPC at the end of IV anesthesia and inhalation anesthesia. Secondary outcomes were time to loss/recovery of palpebral reflex, finish intubation and awakening, MAC, blood concentration/partial pressure at MAC and awakening, correlation between blood partial pressure and gas monitor, and the safety of emulsions. RESULTS: BGPC showed no difference between IV and inhaled anesthesia (0.859 [0.850-0.887] vs 0.813 [0.791-0.901]; P = .313). Induction and emergence from anesthesia were more rapid in IV anesthesia of emulsion than inhalation anesthesia. MAC of emulsion (1.33% [1.11-1.45]) was lower than that of inhalation (2.40% [2.33-2.48]; P = .031), although there was no significant difference in blood concentration. End-tidal sevoflurane concentration could be estimated using gas monitor during IV anesthesia of emulsion. No major complications were observed. CONCLUSIONS: IV anesthesia with emulsion did not increase the BGCP significantly compared to inhalation anesthesia. It was suggested that the anesthetic potency of this emulsion may be equal to or more than that of inhalation.
引用
- Morohashi T, Itakura S, Shimokawa KI, et al. Anesthetic Potency of Intravenous Infusion of 20% Emulsified Sevoflurane and Effect on the Blood-Gas Partition Coefficient in Dogs. Anesth Analg. 2021. PMID: 33105277. doi:10.1213/ANE.0000000000005232
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。