双腔支气管导管导致气道破裂:187例病例综述
该综述汇总文献中由双腔支气管导管(DLT)导致气道破裂的187例病例,分析可能诱因、诊断、治疗及结局。破裂多位于气管(52.4%)和左主支气管(37.4%),常见诱因包括导丝使用、套囊过度充气、多次调整导管位置、困难插管及DLT尺寸过大。多数术中诊断(82.7%),以手术修复为主(78.6%),死亡率8.8%。
要点
- DLT所致气道破裂虽罕见但危及生命,死亡率8.8%。
- 常见诱因:导丝、套囊过度充气、反复调整导管、困难插管、DLT过大。
- 多数术中诊断,首选手术修复,年龄、性别等与死亡率无关。
核心结论
- DLT导致的气道破裂死亡率8.8%,年龄、性别、破裂部位、诊断时机及治疗方式与死亡率无关。
研究设计与样本
- 文献综述:检索PubMed、EMBASE、Ovid、万方和CNKI,纳入105篇单病例报告和22篇病例系列,共187例患者。
主要发现
- 破裂部位:气管98例(52.4%),左主支气管70例(37.4%)。
- 常见诱因:导丝使用、套囊过度充气、多次调整DLT位置、困难插管、DLT尺寸过大。
- 诊断时机:术中诊断138例(82.7%)。
- 主要表现:纵隔气肿、漏气、低氧血症、皮下气肿。
- 治疗:手术修复147例(78.6%)。
临床怎么用
- 使用DLT时应避免套囊过度充气、反复调整位置及选择过大尺寸,以降低气道破裂风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The double-lumen tubes (DLTs) are the most widely used devices to provide perioperative lung isolation. Airway rupture is a rare but life-threatening complication of DLTs. The primary aim of this review was to collect all cases reported in the literature about airway rupture caused by DLTs and to describe the reported possible contributors, diagnosis, treatment, and outcomes of this complication. Another aim of this review was to assess the possible factors associated with mortality after airway rupture by DLTs. A comprehensive literature search for all cases of airway rupture caused by DLTs was performed in the PubMed, EMBASE, Ovid, Wanfang Database, and CNKI. The extracted data included age, sex, height, weight, type of operation, type and size of DLT, site of airway rupture, possible contributors, clinical presentation, diagnosis timing, treatment, and outcome. We included 105 single case reports and 22 case series with a total number of 187 patients. Most of the ruptures were in the trachea (n = 98, 52.4%) and left main bronchus (n = 70, 37.4%). The common possible contributors include use of a stylet, cuff overdistention, multiple attempts to adjust the position of a DLT, difficult intubation, and use of an oversized DLT. Most of the airway ruptures were diagnosed intraoperatively (n = 138, 82.7%). Pneumomediastinum, air leakage, hypoxemia, and subcutaneous emphysema were the common clinical manifestations. Most patients were treated with surgical repair (n = 147, 78.6%). The mortality of the patients with airway rupture by DLTs was 8.8%. Age, sex, site of rupture, diagnosis timing, and method of treatment were not found to be associated with mortality.
引用
- Liu S, Mao Y, Qiu P, et al. Airway Rupture Caused by Double-Lumen Tubes: A Review of 187 Cases. Anesth Analg. 2020. PMID: 33079871. doi:10.1213/ANE.0000000000004669