尸体研究:超声引导肋间臂神经近端与远端阻滞的临床超声解剖
该尸体研究在6具新鲜尸体上描述肋间臂神经(ICBN)与毗邻结构的解剖关系,并提出两种超声引导平面阻滞技术:近端法于第二肋下缘前锯肌内侧缘内侧注射,远端法于腋动脉尾侧3-4 cm背阔肌表面注射。在7侧半胸和腋窝实施阻滞后记录染料染色,结果显示近端阻滞使90%的ICBN起源染色,远端阻滞使所有终末支及43%的腋支染色。
要点
- 近端ICBN阻滞定位第二肋下缘前锯肌内侧缘内侧,90%神经起源可被染色。
- 远端ICBN阻滞定位腋动脉尾侧3-4 cm背阔肌表面,终末支全部染色。
- 所有ICBN均起自第二肋间神经,34.6%接受第一或第三肋间神经贡献。
核心结论
- 近端与远端ICBN阻滞利用易于识别的超声解剖标志,均可实现ICBN的染料均匀扩散。
- 作者鼓励在临床研究中进一步验证这两种技术。
研究设计与样本
- 尸体解剖研究,在6具新鲜尸体上探究ICBN与毗邻结构的解剖关系。
- 在7侧半胸和腋窝实施超声引导近端与远端ICBN阻滞,记录染料染色范围。
主要发现
- 所有ICBN均起自第二肋间神经,34.6%接受第一或第三肋间神经贡献。
- 所有ICBN在腋窝发出腋支并走向臂后内侧。
- 近端ICBN阻滞后,90%的ICBN起源被染色。
- 远端ICBN阻滞后,所有终末支及43%的腋支被染色。
关键数值与推荐
- 近端法:于第二肋下缘前锯肌内侧缘内侧注射。
- 远端法:于腋动脉尾侧3-4 cm背阔肌表面注射。
临床怎么用
- 可依据第二肋下缘前锯肌内侧缘内侧或腋动脉尾侧3-4 cm背阔肌表面两个标志定位ICBN。
- 近端阻滞侧重覆盖ICBN起源,远端阻滞侧重覆盖终末支及部分腋支。
局限性
- 研究为尸体染料扩散研究,样本为6具新鲜尸体、7侧半胸和腋窝。
- 两种技术的临床效果尚未在临床研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: The intercostobrachial nerve (ICBN) has significant anatomical variation. Localization of the ICBN requires an operator's skill. This cadaveric study aims to describe two simple ultrasound-guided plane blocks of the ICBN when it emerges at the chest wall (proximal approach) and passes through the axillary fossa (distal approach). METHODS: The anatomical relation of the ICBN and adjacent structures was investigated in six fresh cadavers. Thereafter, we described two potential techniques of the ICBN block. The proximal approach was an injection medial to the medial border of the serratus anterior muscle at the inferior border of the second rib. The distal approach was an injection on the surface of the latissimus dorsi muscle at 3-4 cm caudal to the axillary artery. The ultrasound-guided proximal and distal ICBN blocks were performed in seven hemithoraxes and axillary fossae. We recorded dye staining on the ICBN, its branches and clinically correlated structures. RESULTS: All ICBNs originated from the second intercostal nerve and 34.6% received a contribution from the first or third intercostal nerve. All ICBNs gave off axillary branches in the axillary fossa and ran towards the posteromedial aspect of the arm. Following the proximal ICBN block, dye stained on 90% of all ICBN's origins. After the distal ICBN block, all terminal branches and 43% of the axillary branches of the ICBN were stained. CONCLUSIONS: The proximal and distal ICBN blocks, using easily recognized sonoanatomical landmarks, provided consistent dye spread to the ICBN. We encourage further validation of these two techniques in clinical studies.
引用
- Samerchua A, Leurcharusmee P, Panjasawatwong K, et al. Cadaveric study identifying clinical sonoanatomy for proximal and distal approaches of ultrasound-guided intercostobrachial nerve block. Reg Anesth Pain Med. 2020. PMID: 32928992. doi:10.1136/rapm-2020-101783
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。