文献速递区域麻醉与超声术前评估与围术期医学

超声引导椎旁阻滞用于乳腺手术的并发症发生率

Complication rate of ultrasound-guided paravertebral block for breast surgery.
PubMed 文献 · Reg Anesth Pain Med · 2020-08-17

该研究回顾性分析了5年内529例乳腺手术患者共2163次非连续超声引导胸椎旁阻滞,术中未发现胸膜穿刺,术后胸片发现2例气胸(每1000例手术3.6例,95%CI 0.5-13.6),无局麻药全身毒性事件。结论认为经旁矢状面入路非连续超声引导胸椎旁阻滞后气胸不常见,发生率与单纯乳腺手术后气胸相似。

要点

  • 非连续超声引导胸椎旁阻滞用于乳腺手术时胸膜穿刺率为0。
  • 术后气胸发生率为每1000例手术3.6例(95%CI 0.5-13.6)。
  • 未发生局麻药全身毒性或需脂肪乳治疗的事件。

核心结论

  • 经旁矢状面入路非连续超声引导胸椎旁阻滞后气胸不常见,发生率与单纯乳腺手术后气胸相似。

研究设计与样本

  • 回顾性查询本机构电子数据库5年期间接受乳腺手术并实施胸椎旁阻滞的患者,共529例患者、2163次胸椎旁注射。

主要发现

  • 阻滞操作过程中未识别到胸膜穿刺。
  • 术后胸片发现2例气胸,发生率为每1000例手术3.6例(95%CI 0.5-13.6),每1000个阻滞节段0.9例(95%CI 0.1-3.3)。
  • 未发生局麻药全身毒性病例,也无相关脂肪乳治疗给药。

临床怎么用

  • 乳腺手术采用非连续超声引导胸椎旁阻滞时,气胸风险较低,但仍需术后关注气胸可能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Thoracic paravertebral blockade is often used as an anesthetic and/or analgesic technique for breast surgery. With ultrasound guidance, the rate of complications is speculated to be lower than when using landmark-based techniques. This investigation aimed to quantify the incidence of pleural puncture and pneumothorax following non-continuous ultrasound-guided thoracic paravertebral blockade for breast surgery. METHODS: Patients who received thoracic paravertebral blockade for breast surgery were identified by retrospective query of our institution's electronic database over a 5-year period. Data collected included patient demographics, level of block, type and volume of local anesthetic, occurrence of pleural puncture, occurrence of pneumothorax, evidence of local anesthetic toxicity, and patient vital signs. The incidence of block complications, including pleural puncture, pneumothorax, and local anesthetic toxicity, were ascertained. RESULTS: 529 patients underwent 2163 thoracic paravertebral injections. Zero pleural punctures were identified during block performance; however, two patients were found to have a pneumothorax on postoperative chest X-ray (3.6 per 1000 surgeries, 95% CI 0.5 to 13.6; 0.9 per 1000 levels blocked, 95% CI 0.1 to 3.3). There were no cases of local anesthetic systemic toxicity or associated lipid emulsion therapy administration. CONCLUSIONS: Pneumothorax following non-continuous ultrasound-guided thoracic paravertebral block using a parasagittal approach is an uncommon occurrence, with a similar rate to pneumothorax following breast surgery alone.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Niesen AD, Jacob AK, Law LA, et al. Complication rate of ultrasound-guided paravertebral block for breast surgery. Reg Anesth Pain Med. 2020. PMID: 32817361. doi:10.1136/rapm-2020-101402

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。