文献速递气道管理术前评估与围术期医学

C-MAC PM可视喉镜用于院前心脏骤停与非心脏骤停急诊患者气管插管首次成功率比较

First pass success of tracheal intubation using the C-MAC PM videolaryngoscope as first-line device in prehospital cardiac arrest compared with other emergencies: An observational study.
PubMed 文献 · Eur J Anaesthesiol · 2021-01-01

该研究基于德国一家直升机应急医疗服务(HEMS)2009年5月至2018年7月的前瞻性数据,纳入1006例由麻醉专科医师行院前高级气道管理的患者,比较心脏骤停心肺复苏(CPR)组与其他急诊(非CPR组)使用C-MAC PM可视喉镜作为一线设备的插管成功率。结果显示CPR组首次成功率低于非CPR组(84.4% vs 91.4%,P=0.01),且CPR组直接喉镜下更常见临床不利的声门视野(Cormack-Lehane 3或4级:37.2% vs 26.7%,P=0.0071),可视喉镜可改善声门视野分级(P<0.0001),良好声门视野下首次成功 odds 约提高12倍(OR 12.6,CI 6.70-23.65)。

要点

  • CPR组首次插管成功率低于非CPR组(84.4% vs 91.4%,P=0.01)。
  • CPR组直接喉镜下Cormack-Lehane 3或4级视野更常见(37.2% vs 26.7%,P=0.0071)。
  • 良好声门视野下首次插管成功 odds 约提高12倍(OR 12.6,CI 6.70-23.65)。

核心结论

  • 由麻醉医师配备的HEMS中气道管理首次成功率高,但即使熟练操作者常规使用C-MAC PM可视喉镜,需CPR的患者院前高级气道管理首次尝试成功仍更困难。

研究设计与样本

  • 前瞻性收集的院前高级气道管理核心变量持续分析,单中心直升机应急医疗服务(HEMS)‘Christoph 22’,德国乌尔姆军医院,2009年5月至2018年7月,纳入1006例由值班麻醉专科医师行院前高级气道管理的HEMS患者。

主要发现

  • 所有患者包括 rescue 技术在内均获得通畅气道;CPR组首次成功率低于非CPR组(84.4% vs 91.4%,P=0.01)。
  • CPR组直接喉镜下Cormack-Lehane 3或4级视野比例高于非CPR组(37.2% vs 26.7%,P=0.0071)。
  • 使用可视喉镜可将临床不利的Cormack-Lehane分级改善为1或2级(P<0.0001)。
  • 良好声门视野下首次插管成功的 odds 约为不良声门视野的12倍(OR 12.6,CI 6.70至23.65)。

临床怎么用

  • 院前心脏骤停患者使用C-MAC PM可视喉镜行气管插管时首次成功率低于其他急诊患者,应预期更高操作难度并做好准备。
  • 直接喉镜下声门视野不佳时,改用可视喉镜视野可改善Cormack-Lehane分级并可能提高首次插管成功率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Successful airway management is a priority in the resuscitation of critically ill or traumatised patients. Several studies have demonstrated the importance of achieving maximum first pass success, particularly in prehospital advanced airway management. OBJECTIVE: To compare success rates of emergency intubations between patients requiring cardiopulmonary resuscitation (CPR) for cardiac arrest (CPR group) and other emergencies (non-CPR group) using the C-MAC PM videolaryngoscope. DESIGN: Ongoing analysis of prospective collected prehospital advanced airway management core variables. SETTING: Single helicopter emergency medical service (HEMS) 'Christoph 22', Ulm Military Hospital, Germany, May 2009 to July 2018. PATIENTS: We included all 1006 HEMS patients on whom prehospital advanced airway management was performed by board-certified anaesthesiologists on call at HEMS 'Christoph 22'. INTERVENTIONS: The C-MAC PM was used as the first-line device. The initial direct laryngoscopy was carried out using the C-MAC PM without the monitor in sight. After scoring the direct laryngoscopic view according to the Cormack and Lehane grade, the monitor was folded within the sight of the physician and tracheal intubation was performed using the videolaryngoscopic view without removing the blade. MAIN OUTCOME MEASURES: The primary outcome was successful airway management. Secondary outcomes were the patient's position during airway management, necessity for suction, direct and videolaryngoscopic view according to Cormack and Lehane grading, as well as number of attempts needed for successful intubation. RESULTS: A patent airway was achieved in all patients including rescue techniques. There was a lower first pass success rate in the CPR group compared with the non-CPR group (84.4 vs. 91.4%, P = 0.01). In the CPR group, direct laryngoscopy resulted more often in a clinically unfavourable (Cormack and Lehane grade 3 or 4) glottic view (CPR vs. non-CPR-group 37.2 vs. 26.7%, P = 0.0071). Using videolaryngoscopy reduced the clinically unfavourable grading to Cormack and Lehane 1 or 2 (P < 0.0001). The odds of achieving first pass success were approximately 12-fold higher with a favourable glottic view than with an unfavourable glottic view (OR 12.6, CI, 6.70 to 23.65). CONCLUSION: Airway management in an anaesthesiologist-staffed HEMS is associated with a high first pass success rate but even with skilled providers using the C-MAC PM videolaryngoscope routinely, patients who require CPR offer more difficulties for successful prehospital advanced airway management at the first attempt. TRIAL REGISTRATION: German Clinical trials register (drks.de) DRKS00020484.

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Hossfeld B, Thierbach S, Allgoewer A, et al. First pass success of tracheal intubation using the C-MAC PM videolaryngoscope as first-line device in prehospital cardiac arrest compared with other emergencies: An observational study. Eur J Anaesthesiol. 2021. PMID: 32833853. doi:10.1097/EJA.0000000000001286

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。