文献速递区域麻醉与超声疼痛医学

膝神经阻滞与射频消融:现行与修订解剖靶点的尸体模型证据

Current versus revised anatomical targets for genicular nerve blockade and radiofrequency ablation: evidence from a cadaveric model.
PubMed 文献 · Reg Anesth Pain Med · 2020-06-18

修订靶点至膝上内侧神经和膝上外侧神经降支的距离显著更短,准确率更高;修订靶点对腓返神经和隐神经髌下支的准确率为100%。结论为修订靶点较现行靶点更准确。

要点

  • 修订靶点至膝上内侧神经距离0.7 mm,显著短于现行靶点17.8 mm(p=0.01)。
  • 修订靶点至膝上外侧神经降支距离3.7 mm,显著短于现行靶点24.4 mm(p=0.02)。
  • 修订靶点对膝上内侧神经和膝上外侧神经的准确率分别为100%和64%,均高于现行靶点。

核心结论

  • 修订靶点用于膝神经射频消融比现行靶点更准确。

主要发现

  • 修订靶点至膝上内侧神经的平均距离为0.7 mm,现行靶点为17.8 mm(p=0.01)。
  • 修订靶点至膝上外侧神经降支的平均距离为3.7 mm,现行靶点为24.4 mm(p=0.02)。
  • 膝上内侧神经的准确率修订靶点为100%、现行靶点为0%;膝上外侧神经的准确率修订靶点为64%、现行靶点为35%。
  • 修订靶点对腓返神经和隐神经髌下支的准确率均为100%。

关键数值与推荐

  • 修订靶点至膝上内侧神经距离0.7 mm vs 现行17.8 mm(p=0.01)。
  • 修订靶点至膝上外侧神经降支距离3.7 mm vs 现行24.4 mm(p=0.02)。
  • 膝上内侧神经准确率修订100% vs 现行0%;膝上外侧神经准确率修订64% vs 现行35%。
  • 修订靶点对腓返神经和隐神经髌下支的准确率为100%。

临床怎么用

  • 透视引导膝神经射频消融时可考虑采用修订解剖靶点以提高神经捕获准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Recent studies have proposed revised anatomical targets to improve accuracy of genicular nerve (GN) radiofrequency ablation (RFA). This study aims to compare the accuracy of classical and revised techniques for fluoroscopic-guided GN-RFA in cadaveric models. MATERIALS AND METHODS: Fourteen knees from seven fresh frozen human cadavers were included in this study. For each cadaver, RF cannulas were placed to capture the GN according to the current targets in one knee, and the revised targets in the other knee, randomly. The stylet was removed from the cannula, plunged into non-diffusible black paint, and reintroduced entirely in the cannula, to create a limited black spot on the tissues at the top of the active tip. Anatomical dissection was performed, and the accuracy of both techniques was compared. RESULTS: The mean distance from the top of the active tip to the nerve was significantly lower with revised than current targets for the superior-medial GN (0.7 mm vs 17.8 mm, p=0.01) and the descending branch of the superior-lateral GN (3.7 mm vs 24.4 mm, p=0.02). In both superior-medial GN and superior-lateral GN, the accuracy rate was higher with revised than current targets: 100% vs 0% and 64% vs 35%, respectively. In addition, the accuracy of revised targets for the recurrent fibular nerve and the infrapatellar branch of saphenous nerve was 100%. CONCLUSION: This study demonstrates that the revised targets are more accurate than the current targets for GN-RFA.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Fonkoue L, Behets CW, Steyaert A, et al. Current versus revised anatomical targets for genicular nerve blockade and radiofrequency ablation: evidence from a cadaveric model. Reg Anesth Pain Med. 2020. PMID: 32561652. doi:10.1136/rapm-2020-101370

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。