超声针尖追踪用于锁骨下臂丛阻滞的随机对照志愿者研究
本研究为随机、对照、观察者盲法交叉试验,纳入26名健康志愿者,由两名麻醉专科医生在有无针尖追踪技术下实施超声引导锁骨下外侧矢状臂丛阻滞。主要结局操作时间在两组间无显著差异(183.0秒 vs 206.8秒,p=0.16),所有次要结局亦无显著差异。结论认为针尖追踪技术未显示显著优势。
要点
- 针尖追踪技术未缩短锁骨下臂丛阻滞的操作时间。
- 所有次要结局(手部运动、阻滞成功率等)均无显著差异。
- 无针尖追踪组有2例志愿者出现霍纳综合征。
核心结论
- 在超声引导锁骨下臂丛阻滞中,主动针尖追踪技术与对照组相比,主要结局和次要结局均无显著差异。
研究设计与样本
- 随机、对照、观察者盲法交叉试验,纳入26名健康志愿者,由两名麻醉专科医生操作。
主要发现
- 平均(标准差)操作时间:针尖追踪组183.0(56.1)秒,对照组206.8(56.2)秒,p=0.16。
- 所有次要结局均无显著差异。
- 无针尖追踪组有2名志愿者出现霍纳综合征,研究中无其他不良事件。
临床怎么用
- 针尖追踪技术可作为辅助手段,但本研究未显示其能改善操作时间或阻滞效果。
局限性
- 研究仅在健康志愿者中进行,由两名专科医生操作,样本量26例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Onvision is a new technology for needle tip detection and tracking in ultrasound-guided regional anesthesia. The system consists of a piezoelectric sensor close to the needle tip and an electronic console integrated in the ultrasound system. The needle tip is visualized by a green circle on the ultrasound screen. The aim of the study was to investigate the effect of the new needle tip tracking technology on in-plane infraclavicular plexus blocks. METHODS: The study was a randomized, controlled, observer blinded cross-over trial in 26 healthy volunteers. Two specialists in anesthesiology performed an ultrasound-guided infraclavicular lateral sagittal brachial plexus block with and without needle tip tracking. Primary outcome was procedure time, measured from insertion of the needle until local anesthesia injection was completed. Secondary outcome measures included the number of hand movements and path lengths (assessed by hand motion analysis), block success rate, onset time and duration, discomfort experienced by the volunteers, and the anesthesiologists' confidence as to whether their block would be successful or not. RESULTS: Mean (SD) procedure time was 183.0 (56.1) s with and 206.8 (56.2) s without needle tip tracking (p=0.16). There were no significant differences in any of the secondary outcomes. Two volunteers' experienced Horner syndrome after blocks without needle tip tracking. No other adverse events occurred during the study. CONCLUSION: Our study on needle tip tracking for infraclavicular blocks did not reveal any significant differences between active needle tip tracking and the control procedures, neither for primary outcome nor secondary outcome measurements. TRIAL REGISTRATION NUMBER: NCT03631914.
引用
- Kåsine T, Romundstad L, Rosseland LA, et al. Ultrasonographic needle tip tracking for in-plane infraclavicular brachialis plexus blocks: a randomized controlled volunteer study. Reg Anesth Pain Med. 2020. PMID: 32540878. doi:10.1136/rapm-2020-101349
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。