气溶胶箱对COVID-19患者插管影响的现场模拟交叉研究
结果显示使用气溶胶箱显著延长插管时间,并增加首次插管失败率和个人防护装备破损风险。
要点
- 使用气溶胶箱显著延长插管时间,可能增加患者缺氧风险。
- 气溶胶箱降低首次插管成功率,并可能导致个人防护装备破损。
- 在进一步研究前,气溶胶箱不应被视为安全的临床设备。
核心结论
- 气溶胶箱可能延长插管时间并增加患者缺氧风险,还可能损坏常规个人防护装备,使临床医生面临感染风险。
主要发现
- 无箱插管时间中位数42.9秒,显著短于早期代箱82.1秒(p=0.002)和最新代箱52.4秒(p=0.008)。
- 无箱时所有麻醉医生首次插管成功;早期代箱和最新代箱首次成功率分别为75%和83%。
- 无箱时无插管超过1分钟;使用箱时14次(58%)超过1分钟,4次(17%)超过2分钟(包括一次失败)。
- 早期代箱发生1次个人防护装备破损,最新代箱发生7次破损。
临床怎么用
- 临床使用气溶胶箱前应权衡其延长插管时间和增加防护装备破损的风险。
局限性
- 本研究为模拟研究,结果可能不完全适用于临床实际。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The coronavirus disease 2019 pandemic has led to the manufacturing of novel devices to protect clinicians from the risk of transmission, including the aerosol box for use during tracheal intubation. We evaluated the impact of two aerosol boxes (an early-generation box and a latest-generation box) on intubations in patients with severe coronavirus disease 2019 with an in-situ simulation crossover study. The simulated process complied with the Safe Airway Society coronavirus disease 2019 airway management guidelines. The primary outcome was intubation time; secondary outcomes included first-pass success and breaches to personal protective equipment. All intubations were performed by specialist (consultant) anaesthetists and video recorded. Twelve anaesthetists performed 36 intubations. Intubation time with no aerosol box was significantly shorter than with the early-generation box (median (IQR [range]) 42.9 (32.9-46.9 [30.9-57.6])s vs. 82.1 (45.1-98.3 [30.8-180.0])s p = 0.002) and the latest-generation box (52.4 (43.1-70.3 [35.7-169.2])s, p = 0.008). No intubations without a box took more than 1 min, whereas 14 (58%) intubations with a box took over 1 min and 4 (17%) took over 2 min (including one failure). Without an aerosol box, all anaesthetists obtained first-pass success. With the early-generation and latest-generation boxes, 9 (75%) and 10 (83%) participants obtained first-pass success, respectively. One breach of personal protective equipment occurred using the early-generation box and seven breaches occurred using the latest-generation box. Aerosol boxes may increase intubation times and therefore expose patients to the risk of hypoxia. They may cause damage to conventional personal protective equipment and therefore place clinicians at risk of infection. Further research is required before these devices can be considered safe for clinical use.
引用
- Begley JL, Lavery KE, Nickson CP, et al. The aerosol box for intubation in coronavirus disease 2019 patients: an in-situ simulation crossover study. Anaesthesia. 2020. PMID: 32397008. doi:10.1111/anae.15115
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。