文献速递气道管理

模拟无法插管无法氧合场景下颈部前入路气道救援:刀-指-套管与刀-指-探条在绵羊模型中的比较

Front-of-neck airway rescue with impalpable anatomy during a simulated cannot intubate, cannot oxygenate scenario: scalpel-finger-cannula versus scalpel-finger-bougie in a sheep model.
PubMed 文献 · Br J Anaesth · 2020-05-25

在解剖标志不可触及的CICO模拟场景中,35名气道培训参与者随机顺序在麻醉绵羊上实施刀-指-套管和刀-指-探条两种技术。刀-指-套管首次给氧时间更短,3分钟内成功给氧比例更高(97% vs 63%,P<0.001),且两种技术均无重大并发症。

要点

  • 刀-指-套管较刀-指-探条缩短首次给氧时间(多因素HR=8.87,95%CI 4.31-18.18,P<0.001)。
  • 刀-指-套管在CICO声明后3分钟内成功给氧比例更高(97% vs 63%,P<0.001)。
  • 刀-指-套管首次二氧化碳图读数时间较长(+89秒,95%CI 69-110,P<0.001)。

核心结论

  • 在解剖标志不可触及的绵羊模拟CICO场景中,刀-指-套管技术的给氧表现优于刀-指-探条。

研究设计与样本

  • 高保真绵羊CICO模拟研究,35名连续合格的气道培训参与者随机顺序实施两种技术。

主要发现

  • 刀-指-套管首次给氧时间更短,单因素HR=11.37(95%CI 5.14-25.13,P<0.001),多因素HR=8.87(95%CI 4.31-18.18,P<0.001)。
  • 多因素模型中,顾问级别较住院医师级别首次给氧更快(HR=3.28,95%CI 1.36-7.95,P=0.008)。
  • 刀-指-套管3分钟内成功给氧且≤2次尝试的比例更高(97% vs 63%,P<0.001)。
  • 仅分析成功病例,刀-指-套管动脉氧饱和度改善更早(-25秒,95%CI -35至-15,P<0.001),但首次二氧化碳图读数时间更长(+89秒,95%CI 69至110,P<0.001)。
  • 两组均无重大并发症发生。

关键数值与推荐

  • 刀-指-套管3分钟内成功给氧且≤2次尝试的比例为97%,刀-指-探条为63%(P<0.001)。

临床怎么用

  • 在解剖标志不可触及的CICO场景中,可优先考虑刀-指-套管技术以加快氧合救援。

局限性

  • 研究为绵羊模拟模型,结果外推至临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Front-of-neck airway rescue in a cannot intubate, cannot oxygenate (CICO) scenario with impalpable anatomy is particularly challenging. Several techniques have been described based on a midline vertical neck incision with subsequent finger dissection, followed by either a cannula or scalpel puncture of the now palpated airway. We explored whether the speed of rescue oxygenation differs between these techniques. METHODS: In a high-fidelity simulation of a CICO scenario in anaesthetised Merino sheep with impalpable front-of-neck anatomy, 35 consecutive eligible participants undergoing airway training performed scalpel-finger-cannula and scalpel-finger-bougie in a random order. The primary outcome was time from airway palpation to first oxygen delivery. Data, were analysed with Cox proportional hazards. RESULTS: Scalpel-finger-cannula was associated with shorter time to first oxygen delivery on univariate (hazard ratio [HR]=11.37; 95% confidence interval [CI], 5.14-25.13; P<0.001) and multivariate (HR=8.87; 95% CI, 4.31-18.18; P<0.001) analyses. In the multivariable model, consultant grade was also associated with quicker first oxygen delivery compared with registrar grade (HR=3.28; 95% CI, 1.36-7.95; P=0.008). With scalpel-finger-cannula, successful oxygen delivery within 3 min of CICO declaration and ≤2 attempts was more frequent; 97% vs 63%, P<0.001. In analyses of successful cases only, scalpel-finger-cannula resulted in earlier improvement in arterial oxygen saturations (-25 s; 95% CI, -35 to -15; P<0.001), but a longer time to first capnography reading (+89 s; 95% CI, 69 to 110; P<0.001). No major complications occurred in either arm. CONCLUSIONS: The scalpel-finger-cannula technique was associated with superior oxygen delivery performance during a simulated CICO scenario in sheep with impalpable front-of-neck anatomy.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Heard A, Gordon H, Douglas S, et al. Front-of-neck airway rescue with impalpable anatomy during a simulated cannot intubate, cannot oxygenate scenario: scalpel-finger-cannula versus scalpel-finger-bougie in a sheep model. Br J Anaesth. 2020. PMID: 32466843. doi:10.1016/j.bja.2020.04.067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。