McGrath视频喉镜与Macintosh直接喉镜在病态肥胖患者插管中的随机对照试验
该随机对照试验纳入130例BMI≥40 kg/m²的择期手术患者,比较McGrath视频喉镜与Macintosh直接喉镜对声门视野的改善情况,采用Cormack-Lehane分级评估。结论认为McGrath视频喉镜可改善病态肥胖患者的声门视野,但需大样本试验明确其能否减少插管尝试和失败。
要点
- 病态肥胖患者使用McGrath视频喉镜可显著改善声门视野(OR 4.6)。
- 视频喉镜与直接喉镜在插管尝试次数和失败插管上未见差异。
- 需大样本临床试验验证改善视野能否减少插管尝试和失败。
核心结论
- 在病态肥胖患者中,McGrath视频喉镜较Macintosh直接喉镜显著改善声门视野,但插管尝试次数和失败插管无差异。
研究设计与样本
- 随机对照试验,纳入130例年龄18-99岁、BMI≥40 kg/m²、ASA I-III级的择期手术患者,1:1随机分组并按BMI≥50 kg/m²分层,比较McGrath视频喉镜与Macintosh直接喉镜。
主要发现
- 未观察到插管尝试次数和失败插管增加或减少的证据。
关键数值与推荐
- 声门视野改善定义为Cormack-Lehane分级改善,采用比例优势逻辑回归模型比较。
临床怎么用
- 对病态肥胖患者可优先考虑使用McGrath视频喉镜以改善声门视野,但尚不能据此认为可减少插管尝试次数或失败率。
局限性
- 原文未明确报告局限性;结论指出需大样本临床试验确定视频喉镜改善视野能否减少插管尝试和失败。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Two-thirds of the US population is considered obese and about 8% morbidly obese. Obese patients may present a unique challenge to anesthesia clinicians in airway management. Videolaryngoscopes may provide better airway visualization, which theoretically improves intubation success. However, previous work in morbidly obese patients was limited. We therefore tested the primary hypothesis that the use of McGrath video laryngoscope improves visualization of the vocal cords versus Macintosh direct laryngoscopy (Teleflex, Morrisville, NC) in morbidly obese patients. METHODS: We enrolled 130 surgical patients, aged 18-99 years, with a body mass index ≥40 kg/m and American Society of Anaesthesiologists (ASA) physical status I-III. Patients were randomly allocated 1:1-stratified for patient's body mass index ≥50 kg/m-to McGrath video laryngoscope versus direct laryngoscopy with a Macintosh blade. The study groups were compared on glottis visualization, defined as improved Cormack and Lehane classification, with proportional odds logistic regression model. RESULTS: McGrath video laryngoscope provided significantly better glottis visualization than Macintosh direct laryngoscopy with an estimated odds ratio of 4.6 (95% confidence interval [CI], 2.2-9.8; P < .01). We did not observe any evidence that number of intubation attempts and failed intubations increased or decreased. CONCLUSIONS: McGrath video laryngoscope improves glottis visualization versus Macintosh direct laryngoscopy in morbidly obese patients. Large clinical trials are needed to determine whether improved airway visualization with videolaryngoscopy reduces intubation attempts and failures.
引用
- Ruetzler K, Rivas E, Cohen B, et al. McGrath Video Laryngoscope Versus Macintosh Direct Laryngoscopy for Intubation of Morbidly Obese Patients: A Randomized Trial. Anesth Analg. 2020. PMID: 32175948. doi:10.1213/ANE.0000000000004747
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。