文献速递产科麻醉气道管理

产科患者高流量鼻氧与标准面罩预氧合有效时间间隔的测定

Determining the effective pre-oxygenation interval in obstetric patients using high-flow nasal oxygen and standard flow rate facemask: a biased-coin up-down sequential allocation trial.
PubMed 文献 · Anaesthesia · 2020-02-11

该研究采用偏币上下序贯分配法,在80名健康产妇中比较标准流量面罩与高流量鼻氧达到呼气末氧浓度≥90%所需的有效时间间隔。标准面罩组90%产妇达标时间为3.6分钟(95%CI 3.3-6.7),而高流量鼻氧组即使8分钟也无法使90%产妇达标。

要点

  • 标准面罩预氧合3.6分钟可使90%产妇呼气末氧≥90%。
  • 高流量鼻氧即使8分钟也无法使90%产妇达到呼气末氧≥90%。
  • 高流量鼻氧4分钟后预氧合成功率不再提升。

核心结论

  • 标准流量面罩预氧合使90%产妇达到呼气末氧≥90%的有效时间间隔为3.6分钟(95%CI 3.3-6.7分钟)。
  • 高流量鼻氧组(无论是否加用简单面罩)即使8分钟也无法估计使90%产妇达标的有效时间间隔。

研究设计与样本

  • 采用偏币上下序贯分配法,纳入80名健康产妇,随机分为标准面罩组(n=40)和高流量鼻氧组(n=40)。
  • 高流量鼻氧组中一半产妇加用简单无流量面罩以减少空气混入。

主要发现

  • 标准面罩组90%产妇达标有效时间间隔为3.6分钟(95%CI 3.3-6.7分钟)。
  • 高流量鼻氧组8分钟不足以使55%产妇达标,加用简单面罩组8分钟不足以使92%产妇达标。
  • 预氧合3分钟时,标准面罩组71%产妇达标,高流量鼻氧组0%达标。
  • 预氧合4分钟时,标准面罩组100%达标,高流量鼻氧加简单面罩组80%达标,高流量鼻氧组67%达标。
  • 超过4分钟后,高流量鼻氧预氧合成功率无进一步改善。

关键数值与推荐

  • 目标终点为呼气末氧浓度≥90%。
  • 标准面罩组90%产妇达标有效时间间隔为3.6分钟(95%CI 3.3-6.7分钟)。

临床怎么用

  • 在产科患者预氧合中,标准流量面罩可在约3.6分钟内使90%产妇达到呼气末氧≥90%。
  • 高流量鼻氧在本研究条件下即使8分钟也难以使90%产妇达到目标终点,选择时需考虑此局限。

局限性

  • 研究仅纳入健康产妇,结论外推需谨慎。
  • 高流量鼻氧组8分钟未能估计有效时间间隔,无法确定所需更长时间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Using biased-coin sequential allocation, we sought to determine the effective time interval in 90% of healthy parturients to achieve a target endpoint end-tidal oxygen of ≥ 90% using standard flow rate facemask and high-flow nasal oxygen. Eighty healthy parturients were randomly assigned to standard facemask (n = 40) or high-flow nasal oxygen (n = 40) groups; half of the parturients in the high-flow nasal oxygen group also used a simple no-flow facemask to minimise air entrainment. The effective time interval for 90% of parturients to achieve the target endpoint for standard facemask was 3.6 min (95%CI 3.3-6.7 min), but could not be estimated for the high-flow nasal oxygen groups with or without an additional simple facemask, as eight minutes was insufficient to achieve the target endpoint for 55% and 92% of parturients, respectively. Furthermore, after three minutes, the target endpoint was reached by 71% in the standard facemask group vs. 0% in the high-flow nasal oxygen groups. After four minutes, the target endpoint was reached by 100% in the standard facemask, 80% in the high-flow nasal oxygen with simple facemask and 67% in the high-flow nasal oxygen groups. Beyond four minutes, there was no improvement in pre-oxygenation success using high-flow nasal oxygen. In conclusion, under the conditions of our study, the effective time interval for 90% of parturients to achieve an end-tidal oxygen ≥ 90% for standard flow rate facemask was estimated to be 3.6 min, but could not be estimated for high-flow nasal oxygen groups even after eight minutes.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Au K, Shippam W, Taylor J, et al. Determining the effective pre-oxygenation interval in obstetric patients using high-flow nasal oxygen and standard flow rate facemask: a biased-coin up-down sequential allocation trial. Anaesthesia. 2020. PMID: 32048278. doi:10.1111/anae.14995

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。