iOS智能手机应用用于围术期功能容量评估的开发与初步研究
本研究基于Apple ResearchKit开发了一款iOS应用,用于在术前评估中实施DASI问卷和6分钟步行试验(6MWT),并比较应用计步与研究级计步器的一致性。
要点
- 基于ResearchKit的iOS应用可实施DASI和6MWT,患者易于完成。
- 应用计步与计步器一致性中等,ICC为0.87(95%CI 0.79-0.92)。
- 距离估算模型纳入步数、步幅、年龄和BMI,R=0.72。
核心结论
- 基于智能手机的功能容量评估使用DASI和6MWT是可行的。
- 应用在术前患者中计步准确性中等,距离估算算法需进一步改进。
研究设计与样本
- 开发基于Apple ResearchKit的iOS应用,实施DASI问卷和6MWT。
主要发现
- 模型整体拟合R=0.72,解释6MWT步行距离变异的72%。
临床怎么用
- 该应用可在术前门诊辅助实施DASI和6MWT,便于患者完成问卷并展示结果。
- 计步和距离估算准确性中等,临床使用前需进一步验证和改进。
局限性
- 为初步研究,样本量有限,需未来研究改进计步准确性和距离估算算法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Functional capacity assessment plays a core role in the preoperative evaluation. The Duke Activity Status Index (DASI) and the 6-minute walk test (6MWT) are 2 methods that have demonstrated the ability to evaluate functional capacity and predict perioperative outcomes. Smartphones offer a novel method to facilitate functional capacity assessment as they can easily administer a survey and accelerometers can track patient activity during a 6MWT. We developed a smartphone application to administer a 6MWT and DASI survey and performed a pilot study to evaluate the accuracy of a smartphone-based functional capacity tool in our Anesthesia and Perioperative Medicine Clinic. METHODS: Using the Apple ResearchKit software platform, we developed an application that administers a DASI survey and 6MWT on an iOS smartphone. The DASI was presented to the patient 1 question on the screen at a time and the application calculated the DASI score and estimated peak oxygen uptake (VO2). The 6MWT used the CMPedometer class from Apple's core motion facility to retrieve accelerometer data collected from the device's motion coprocessor to estimate steps walked. Smartphone estimated steps were compared to a research-grade pedometer using the intraclass correlation coefficient (ICC). Distance walked was directly measured during the 6MWT and we performed a multivariable linear regression with biometric variables to create a distance estimation algorithm to estimate distance walked from the number of steps recorded by the application. RESULTS: Seventy-eight patients were enrolled in the study and completed the protocol. Steps measured by the smartphone application as compared to the pedometer demonstrated moderate agreement with an ICC (95% CI) of 0.87 (0.79-0.92; P = .0001). The variables in the distance estimation algorithm included (β coefficient [slope], 95% CI) steps walked (0.43, 0.29-0.57; P < .001), stride length (0.38, 0.22-0.53; P < .001), age in years (-1.90, -3.06 to -0.75; P = .002), and body mass index (-2.59, -5.13 to -0.06; P = .045). The overall model fit was R = 0.72, which indicates a moderate level of goodness of fit and explains 72% of the variation of distance walked during a 6MWT. CONCLUSIONS: Our pilot study demonstrated that a smartphone-based functional capacity assessment is feasible using the DASI and 6MWT. The DASI was easily completed by patients and the application clearly presented the results of the DASI to providers. Our application measured steps walked during a 6MWT moderately well in a preoperative patient population; however, future studies are needed to improve the smartphone application's step-counting accuracy and distance estimation algorithm.
引用
- Rubin DS, Dalton A, Tank A, et al. Development and Pilot Study of an iOS Smartphone Application for Perioperative Functional Capacity Assessment. Anesth Analg. 2020. PMID: 31567326. doi:10.1213/ANE.0000000000004440
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。