该盲法人体模型研究在104名麻醉医师实施的624次气管插管中,测量了不同喉镜技术对上颌切牙的受力。结果显示,在正常和困难气道中,Hyperangulated视频喉镜(GlideScope和KingVision)较直接喉镜显著降低上颌切牙峰值力,而C-MAC无显著影响。结论提示Hyperangulated视频喉镜可能减少牙齿损伤风险。
要点
- Hyperangulated视频喉镜可降低上颌切牙受力。
- 困难气道中GlideScope和KingVision降力更明显。
- C-MAC对牙齿峰值力无显著影响。
核心结论
- Hyperangulated视频喉镜与上颌切牙受力显著降低相关,可能减少临床牙齿损伤风险。
研究设计与样本
- 盲法人体模型研究,104名麻醉医师使用四种喉镜在正常和困难气道条件下共完成624次气管插管。
主要发现
- 正常气道直接喉镜峰值力中位数(IQR[范围])为21.1(14.0-32.8[2.3-127.6])N,困难气道为29.3(17.7-44.8[3.3-97.2])N。
- 正常气道中,GlideScope和KingVision较直接喉镜峰值力分别降低4.6 N(p=0.006)和10.9 N(p<0.001)。
- 困难气道中,GlideScope和KingVision较直接喉镜峰值力分别降低9.8 N(p<0.001)和17.6 N(p<0.001)。
- C-MAC对中位峰值力无影响。
- 麻醉医师性别不影响峰值力,但经验更丰富者产生更高峰值力。
临床怎么用
- 在牙齿损伤风险较高的患者中,可优先考虑使用Hyperangulated视频喉镜以降低上颌切牙受力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Dental trauma is a common complication of tracheal intubation. As existing evidence is insufficient to validly assess the impact of different laryngoscopy techniques on the incidence of dental trauma, the force exerted onto dental structures during tracheal intubation was investigated. An intubation manikin was equipped with hidden force sensors in all maxillary incisors. Dental force was measured while 104 anaesthetists performed a series of tracheal intubations using direct laryngoscopy with a Macintosh blade, and videolaryngoscopy with a C-MAC® , or the hyperangulated GlideScope® or KingVision® laryngoscopes in both normal and difficult airway conditions. A total of 624 tracheal intubations were analysed. The median (IQR [range]) peak force of direct laryngoscopy in normal airways was 21.1 (14.0-32.8 [2.3-127.6]) N and 29.3 (17.7-44.8 [3.3-97.2]) N in difficult airways. In normal airways, these were lower with the GlideScope and KingVision hyperangulated laryngoscopes, with a reduction of 4.6 N (p = 0.006) and 10.9 N (p < 0.001) compared with direct laryngoscopy, respectively. In difficult airways, these were lower with the GlideScope and KingVision hyperangulated laryngoscopes, with a reduction of 9.8 N (p < 0.001) and 17.6 N (p < 0.001) compared with direct laryngoscopy, respectively. The use of the C-MAC did not have an impact on the median peak force. Although sex of anaesthetists did not affect peak force, more experienced anaesthetists generated a higher peak force than less experienced providers. We conclude that hyperangulated videolaryngoscopy was associated with a significantly decreased force exerted on maxillary incisors and might reduce the risk for dental injury in clinical settings.
引用
- Schieren M, Kleinschmidt J, Schmutz A, et al. Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study. Anaesthesia. 2019. PMID: 31448404. doi:10.1111/anae.14815
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。