文献速递气道管理小儿麻醉

儿童经三种声门上气道装置置入气管导管时套囊与声门距离的随机对照试验

The distance between the glottis and the cuff of a tracheal tube placed through three supraglottic airway devices in children: A randomised controlled trial.
PubMed 文献 · Eur J Anaesthesiol · 2019-01-01

本研究在7岁以下儿童中,通过体内纤维支气管镜评估和体外测量,比较经I-gel、AuraGain和air-Q三种声门上气道装置置入气管导管时套囊相对于声门的位置。主要结局为安全 margin(设备通气出口至近端套囊起点的距离减去通气出口至声门的距离)。结果显示air-Q安全 margin 最大,I-gel最窄,使用I-gel时声带损伤可能性更高。

要点

  • air-Q安全 margin 最大(7.9±1.1 cm),I-gel最窄(1.9±1.1 cm)。
  • 使用AuraGain和air-Q时,小一号和两号气管导管套囊均预测位于声门下方。
  • 使用I-gel时,小一号和两号导管套囊位于声门下方的比例分别为69%和29%。

核心结论

  • AuraGain和air-Q是耐受良好的插管通道,而使用I-gel时声带损伤的可能性更高。

研究设计与样本

  • 随机对照试验,在三级儿童医院进行,对象为7岁以下儿童,采用体内纤维支气管镜评估和体外测量。

主要发现

  • 通气出口至声门距离(均值±标准差):I-gel 3.6±0.6 cm,AuraGain 3.8±0.7 cm,air-Q 2.8±1.0 cm(P < 0.001)。
  • 安全 margin(均值±标准差):I-gel 1.9±1.1 cm,AuraGain 4.4±0.7 cm,air-Q 7.9±1.1 cm。
  • 使用AuraGain和air-Q时,小一号和两号气管导管套囊预测在所有患者中位于声门下方。
  • 使用I-gel时,小一号和两号气管导管套囊位于声门下方的比例分别为69%(95% CI 49.6 to 84.5)和29%(95% CI 14.0 to 48.4)。

临床怎么用

  • 在儿童中经声门上气道装置插管时,优先选择AuraGain或air-Q以增加套囊与声门的安全距离。
  • 使用I-gel作为插管通道时,需警惕套囊位置接近声门、声带损伤风险较高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: After tracheal tube insertion via various types of supraglottic airway devices, the distance from the tube cuff to the vocal cords has not been evaluated in children. OBJECTIVES: The aim of this study was to evaluate the position of a tracheal tube cuff relative to the glottis in children when one of three supraglottic airway devices (I-gel, AuraGain and air-Q laryngeal airway) are used as intubation conduits. DESIGN: A randomised controlled trial. SETTING: Tertiary children's hospital. PATIENTS: Children aged less than 7 years. INTERVENTION: In vivo fibre-optic assessment and in vitro measurement. MAIN OUTCOME MEASURES: The main outcome was the safety margin: the distance between the ventilation outlet of the supraglottic airway device and the beginning of the proximal cuff minus that from the ventilation outlet to the glottis. The maximum inner diameter of the cuffed tracheal tube that could be inserted, the fibre-optic view score and the oropharyngeal leak pressure were also evaluated. RESULTS: The three devices exhibited significant differences in the distance from the ventilation outlet to the glottis (mean ± SD): I-gel 3.6 ± 0.6 cm, AuraGain 3.8 ± 0.7 cm, air-Q 2.8 ± 1.0 cm (P < 0.001). The safety margin was greatest with the air-Q and narrowest with the I-gel: I gel 1.9 ± 1.1 cm, AuraGain 4.4 ± 0.7 cm and air-Q 7.9 ± 1.1 cm. Using the AuraGain and air-Q, the cuffs of the tracheal tubes were predicted to be located below the glottis with one-size and two-size smaller tracheal tubes in all patients. However, using I-gel, the cuffs would be below the glottis in 69% (95% CI 49.6 to 84.5) and 29% (95% CI 14.0 to 48.4) of the patients with a one-size and two-size smaller tube, respectively. CONCLUSION: The AuraGain and air-Q are well tolerated intubating conduits. The possibility of vocal cord damage is higher when the I-gel is used. TRIAL REGISTRATION: www.clinicaltrials.gov (number: NCT03156166).

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Lee JH, Park S, Jang YE, et al. The distance between the glottis and the cuff of a tracheal tube placed through three supraglottic airway devices in children: A randomised controlled trial. Eur J Anaesthesiol. 2019. PMID: 31415305. doi:10.1097/EJA.0000000000001070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。