负压法生成微泡增强平面内技术穿刺针超声显影
该研究在猪肌肉模型中比较负压法、混合法和商业化微泡三种方式向穿刺针内引入微泡后的针显影效果,并采用2×5×5析因设计分析针类型、进针角度和针内内容物类型的影响。结果显示负压法组针显影最高(p<0.001),进针角度是显影的主要决定因素(p<0.001),微泡填充针在40°、50°和60°时均比对照针更可见(p均<0.001)。
要点
- 负压法生成微泡可显著提高平面内技术下穿刺针的超声显影。
- 进针角度是微泡填充针显影的主要决定因素。
- 40°、50°、60°时微泡填充针显影均优于生理盐水对照针。
核心结论
- 在猪肌肉模型中,负压法生成微泡可显著改善40°、50°和60°进针角度下平面内技术穿刺针的超声显影。
研究设计与样本
- 研究分两阶段:第一阶段在猪肌肉模型中比较负压法、混合法和商业化微泡三种方式生成针内微泡的显影效果;第二阶段采用2×5×5析因设计测试针类型、进针角度和针内内容物类型三个因素对微泡填充针显影的影响;两阶段均以无微泡生理盐水填充针为对照,录制进针视频并采集超声图像进行客观显影分析。
主要发现
- 负压法组针显影最高(p<0.001)。
- 针显影主要由进针角度决定(p<0.001)。
- 微泡填充针在40°、50°和60°时均比对照针更可见(p<0.001、p<0.001、p<0.001)。
临床怎么用
- 在平面内技术下,可考虑采用负压法生成微泡填充穿刺针以增强40°至60°进针角度时的超声显影。
局限性
- 研究在猪肌肉模型中进行,结论尚未在人体临床环境中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Our previous work found that needle visibility could be improved by introducing microbubbles into needles. The primary aim of this study was to test the hypothesis that the negative pressure method is superior to two other methods for enhancing needle visibility by introducing microbubbles into needles. The secondary aim was to evaluate the impacts of three factors on the visibility of microbubble-filled needles. METHODS: In the first phase, three methods, including the negative pressure method, the mixing method and commercialized microbubbles, were applied to generate microbubbles inside needles for comparison of visibility in a porcine meat model. In the second phase, three factors were tested with a 2×5×5 factorial design to explore their influence on the visibility of microbubble-filled needles. The three factors included types of needles, insertion angles and types of contents inside needles. Needles filled with saline without microbubbles were used as the control in both phases. Insertion videos were recorded, and ultrasound images of needles were captured for the objective visibility analysis. RESULTS: Needle visibility was highest in the negative pressure method group (p<0.001). Needle visibility was mainly determined by insertion angles (p<0.001). Microbubble-filled needles were more visible than control needles at 40°, 50° and 60° (p<0.001, p<0.001 and p<0.001, respectively). CONCLUSIONS: Needle visibility can be significantly improved by microbubbles generated with the negative pressure method when insertion angles are 40°, 50° and 60° in porcine meat.
引用
- Liu Y, Sun X, Qian W, et al. Enhanced needle visibility by microbubbles generated with negative pressure using an in-plane technique. Reg Anesth Pain Med. 2019. PMID: 31243062. doi:10.1136/rapm-2019-100570
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。