PubMed 文献 · Br J Anaesth · 2019-04-12

一项前瞻性观察研究纳入64名成年女性,比较置入与未置入i-gel®时通过触诊定位环甲膜的准确性。置入i-gel®组准确率为66%(42/64),对照组为36%(23/64),差异有统计学意义(P<0.001)。置入i-gel®可改善触诊定位准确性并降低感知难度。

要点

  • 女性置入i-gel®后触诊定位环甲膜准确率由36%升至66%。
  • i-gel®使环状软骨前移,环甲膜与气管前壁夹角减小。
  • 紧急环甲膜切开前或可保留已置入的声门上气道装置。

核心结论

  • 在成年女性中,置入i-gel®声门上气道装置可提高触诊定位环甲膜的准确性。

研究设计与样本

  • 前瞻性观察研究,纳入64名成年女性,由志愿者在置入与未置入i-gel®条件下进行评估。

主要发现

  • 置入i-gel®组环甲膜定位准确率为66%(42/64),对照组为36%(23/64),P<0.001,平均差异30%(95%CI 12-47%)。
  • 置入i-gel®组视觉模拟评分(VAS)和估计位置与实际环甲膜距离均降低(P<0.001)。
  • 超声分析显示i-gel®组环甲膜与气管前壁平均夹角减小(166° vs 151°,P<0.001),环状软骨位置更靠腹侧。

临床怎么用

  • 在女性紧急环甲膜切开前,可考虑保留已置入的i-gel®而非移除,以利用其前移环状软骨、增强触诊突出的效应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Identification of the cricothyroid membrane is frequently inaccurate in females because of less distinct anatomy compared with males. Supraglottic airway devices cause ventral displacement of the laryngeal structures. We investigated if this would impact on the accuracy of cricothyroid membrane identification using palpation. METHODS: We recruited 64 adult females who underwent assessment by volunteer participants with and without a sited i-gel® supraglottic airway device. The primary outcome was accuracy in identifying the cricothyroid membrane. Secondary outcomes included distance from participant estimate to actual cricothyroid membrane location and perceived difficulty using a visual analogue scale. Ultrasound images were analysed to determine the effect of the i-gel® on the anatomical structures relevant to cricothyroidotomy. RESULTS: The cricothyroid membrane was identified correctly in 42/64 subjects with the i-gel® in place (66%) vs 23/64 of controls (36%; P<0.001, mean difference 30%; 95% confidence interval, 12-47%). VAS (P<0.001) and distance to the cricothyroid membrane (P<0.001) decreased in the intervention group. Analysis of the ultrasound image series showed a reduction in the mean angle between the cricothyroid membrane and anterior wall of the trachea in the i-gel® group, because of the more ventral position of the cricoid cartilage compared with control images (166° vs 151°, P<0.001). CONCLUSIONS: The presence of the i-gel® improved accuracy of identifying the cricothyroid membrane using palpation in females. The cricoid cartilage was pushed ventrally by the i-gel® in the hypopharynx, creating a more palpable prominence. It may therefore be advantageous to retain a sited supraglottic airway, rather than remove it, before performing emergency cricothyroidotomy.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Drew T, Khan W, McCaul C, et al. The effect of i-gel® insertion on the accuracy of cricothyroid membrane identification in adult females: a prospective observational study. Br J Anaesth. 2019. PMID: 30987766. doi:10.1016/j.bja.2019.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。