高吸入氧浓度损害健康儿童肺容积与通气异质性:双盲随机对照试验
结果显示FiO2>0.8组在恢复室出室后功能残气量下降,通气异质性增加且术后24小时持续存在,提示应避免在肺正常儿童中使用FiO2>0.8。
要点
- FiO2>0.8组恢复室出室后功能残气量下降12.0%,24小时后恢复正常。
- FiO2>0.8组术后24小时通气异质性仍持续增加6.1%。
- 两组气道阻力和呼吸组织弹性无差异。
核心结论
- FiO2>0.8降低健康儿童术后早期肺容积,并伴有持续的通气异质性。
- 建议肺正常的麻醉儿童避免使用FiO2>0.8。
研究设计与样本
- 在术前、恢复室出室后和术后24小时进行多次呼吸氮冲洗和强迫振荡测量。
主要发现
- FiO2>0.8组恢复室出室后功能残气量下降-12.0%(95%CI -18.5至-5.5%),P=0.01,24小时后恢复正常。
- 两组恢复室出室后通气异质性均增加,但FiO2>0.8组术后24小时仍持续增加6.1%(95%CI 2.5至9.8%),P=0.02。
- 两组各时间点气道阻力和呼吸组织弹性无差异。
临床怎么用
- 对肺正常的麻醉儿童,应避免术中及诱导/苏醒期使用FiO2>0.8。
- 术后应关注肺容积和通气异质性变化,尤其是高FiO2暴露者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although a high inspired oxygen fraction (FiO2) is commonly used in paediatric anaesthesia, the impact on postoperative lung function is unclear. We compared lung volume, ventilation heterogeneity, and respiratory mechanics in anaesthetised children randomised to receive low or high FiO2 intraoperatively. METHODS: In a double-blind randomised controlled trial, children scheduled for elective surgery were randomly assigned FiO2 100% (n=29) or FiO2 80% (n=29) during anaesthesia induction and emergence. During maintenance of anaesthesia, participants assigned FiO2=100% at induction/emergence received FiO2=80% (FiO2>0.8 group); those randomised to FiO2=80% at induction/emergence received FiO2=35% intraoperatively (FiO2 [0.8→0.35 group]). During spontaneous breathing, we measured the (i) functional residual capacity (FRC) and lung clearance index (ventilation inhomogeneity) by multiple-breath nitrogen washout; and (ii) airway resistance and respiratory tissue elastance by forced oscillations, before operation, after discharge from the recovery room, and 24 h after operation. Mean (95% confidence intervals) are reported. RESULTS: Fifty eight children (12.9 [12.3-13.5] yr) were randomised; 22/29 (high group) and 21/29 (low group) children completed serial multiple-breath nitrogen washout measurements. FRC decreased in the FiO2>0.8 group after discharge from recovery (-12.0 [-18.5 to -5.5]%; P=0.01), but normalised 24 h later. Ventilation inhomogeneity increased in both groups after discharge from recovery, but persisted in the FiO2>0.8 group 24 h after surgery (6.1 [2.5-9.8%]%; P=0.02). Airway resistance and respiratory elastance did not differ between the groups at any time point. CONCLUSIONS: FiO2>0.8 decreases lung volume in the immediate postoperative period, accompanied by persistent ventilation inhomogeneity. These data suggest that FiO2>0.8 should be avoided in anaesthetised children with normal lungs. CLINICAL TRIAL REGISTRATION: NCT02384616.
引用
- Grandville B, Petak F, Albu G, et al. High inspired oxygen fraction impairs lung volume and ventilation heterogeneity in healthy children: a double-blind randomised controlled trial. Br J Anaesth. 2019. PMID: 30916028. doi:10.1016/j.bja.2019.01.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。