文献速递产科麻醉区域麻醉与超声小儿麻醉

新生儿短暂性呼吸急促与择期剖宫产脊髓麻醉下母体低血压相关:回顾性队列研究

Transient Tachypnea of Newborns Is Associated With Maternal Spinal Hypotension During Elective Cesarean Delivery: A Retrospective Cohort Study.
PubMed 文献 · Anesth Analg · 2019-01-01

该回顾性队列研究比较了择期剖宫产中发生新生儿短暂性呼吸急促(TTN)的30例与呼吸正常151例新生儿的母体数据。

要点

  • 择期剖宫产脊髓麻醉后母体收缩压≤90 mm Hg的曲线下面积与新生儿TTN独立相关。
  • TTN组母体去氧肾上腺素和麻黄碱用量显著高于对照组。
  • 未来需前瞻性研究探索母体低血压预防与治疗对TTN的影响。

核心结论

  • 择期剖宫产椎管内麻醉后母体收缩压低于90 mm Hg的程度和持续时间与新生儿短暂性呼吸急促相关。

研究设计与样本

  • 回顾性队列研究,纳入2015年7月至2016年2月期间择期剖宫产分娩的新生儿,TTN组30例,呼吸功能正常对照组151例。

主要发现

  • TTN组平均动脉压曲线下面积中位数0(0-18.6 mm Hg*min),高于对照组0(0-1.1 mm Hg*min),P=0.01。

临床怎么用

  • 择期剖宫产脊髓麻醉期间应关注母体收缩压低于90 mm Hg的程度和持续时间,积极预防和处理低血压。

局限性

  • 回顾性设计,样本量有限,需前瞻性研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The risk for transient tachypnea of newborns, a common cause of respiratory distress in the neonatal period, is 2- to 6-fold higher during elective cesarean delivery compared to vaginal delivery. Here, we evaluated the association between transient tachypnea of newborns and the degree and duration of predelivery maternal hypotension during spinal anesthesia for elective cesarean delivery. METHODS: Demographic data, details of anesthetic management, blood pressure measurements, and vasopressor requirement preceding delivery were compared between transient tachypnea newborns (n = 30) and healthy neonates (n = 151) with normal respiratory function born via elective cesarean delivery between July 2015 and February 2016. The degree and duration of hypotension were assessed using area under the curve for systolic blood pressure (SBP) ≤90 mm Hg and area under the curve for mean arterial pressure ≤65 mm Hg. After adjusting for confounders, multivariable logistic regression was used to evaluate the association between area under the curve for SBP and transient tachypnea of newborns. RESULTS: The median area under the curve for SBP was higher in cases of transient tachypnea of newborns (0.94; interquartile range, 0-28.7 mm Hg*min) compared to healthy controls (0; interquartile range, 0-3.30 mm Hg*min; P = .001). Similarly, median area under the curve for mean arterial pressure was also higher in cases of transient tachypnea of newborns (0; interquartile range, 0-18.6 mm Hg*min) compared to controls (0; interquartile range, 0-1.1 mm Hg*min; P = .01). Mothers of transient tachypnea newborns received significantly higher amounts of phenylephrine and ephedrine compared to controls (P = .001 and 0.01, respectively). Hence, the total vasopressor dose given to mothers in the transient tachypnea of newborn group was much higher than for the control group (P = .001). In the multivariable logistic regression, area under the curve for SBP was significantly associated with transient tachypnea of newborns (odds ratio, 1.02; 95% CI, 1.01-1.04, P = .005) after adjusting for gravidity and the type of anesthetic (spinal versus combined spinal epidural). CONCLUSIONS: Our results suggest that the degree and duration of maternal SBP <90 mm Hg after neuraxial anesthesia during elective cesarean delivery are associated with transient tachypnea of newborns. Future prospective studies should further explore the effects of maternal hypotension, its prevention, and treatment for transient tachypnea of newborns.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Singh S, Lumbreras-Marquez MI, Farber MK, et al. Transient Tachypnea of Newborns Is Associated With Maternal Spinal Hypotension During Elective Cesarean Delivery: A Retrospective Cohort Study. Anesth Analg. 2019. PMID: 30768454. doi:10.1213/ANE.0000000000004064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。