文献速递气道管理

头颈位置变化对超声定位环甲膜的影响:一项观察性研究

Impact of change in head and neck position on ultrasound localisation of the cricothyroid membrane: an observational study.
PubMed 文献 · Anaesthesia · 2018-10-01

该观察性研究纳入22名志愿者,用超声测量中立位与最大后伸位下环甲膜高度及中点皮肤标记位置变化。结果显示后伸位时环甲膜高度增加30%,皮肤中点标记中位移动5mm,12/22例标记移出环甲膜边界。作者建议环甲膜切开术前皮肤标记应于颈部后伸位进行。

要点

  • 颈部后伸位时环甲膜高度增加30%。
  • 中立位标记的环甲膜中点在后伸位中位移动5mm。
  • 12/22例中立位标记在后伸位移出环甲膜边界。

核心结论

  • 环甲膜切开术前皮肤标记应在颈部后伸位进行,而非中立位。

研究设计与样本

  • 观察性研究,纳入22名志愿者,由放射科医生用超声测量环甲膜高度并标记中点。

主要发现

  • 从当前位置到完全后伸位,环甲膜中点皮肤标记中位(IQR[范围])移动5(4-6[0-10])mm。
  • 颈部后伸后,22名受试者中12名的初始皮肤标记移出环甲膜边界。
  • 颈部后伸时环甲膜高度增加30%。

临床怎么用

  • 准备环甲膜切开时,应在颈部后伸位标记皮肤,而非先前建议的中立位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The ideal position for performing surgical cricothyroidotomy is with full neck extension. Some authors have recommended marking the cricothyroid membrane before general anaesthesia, typically with the patient's head and neck in a neutral position. The primary aim of this observational study was to determine whether skin marks made over the centre of the cricothyroid membrane with the head and neck in the neutral position moved outside the boundaries of the membrane when the neck was subsequently extended. The secondary aim was to assess changes in the height of the cricothyroid membrane between the neutral and extended positions. Twenty-two volunteers completed the study. With the head and neck in the neutral position, the distance between the upper and lower borders ('height') of the cricothyroid membrane was measured by a radiologist using ultrasound. The skin was marked over the mid-point of the membrane. The subject then maximally extended the neck, and the measurements and marking were repeated. The skin marking over the centre point of the cricothyroid membrane moved by median (IQR [range]) 5 (4-6 [0-10]) mm when the head and neck were moved from a neutral to a fully extended position. The initial skin mark moved to lie outside the boundary of the cricothyroid membrane in 12 of 22 subjects after extending the neck. The height of the cricothyroid membrane increased by 30% with the neck extended. We recommend that marking the skin in preparation for cricothyroidotomy should be performed with the neck extended, not with the head and neck in the neutral position as previously suggested.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Dixit A, Ramaswamy KK, Perera S, et al. Impact of change in head and neck position on ultrasound localisation of the cricothyroid membrane: an observational study. Anaesthesia. 2018. PMID: 30276793. doi:10.1111/anae.14445

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。