声门上气道装置在困难气道管理中的应用:丹麦麻醉数据库658104例全麻回顾性队列研究
该回顾性队列研究基于丹麦麻醉数据库2008至2012年658104例成人全麻记录,困难气道管理发生率为0.74%(95%CI 0.72-0.76%)。在607例困难气道管理中,声门上气道装置使用或尝试使用率为12.4%(95%CI 11.5-13.3%),成功率为65.1%(95%CI 61.2-68.8%);在无法插管无法面罩通气情形中,使用率为18.9%(95%CI 15.6-22.8%),成功率为62.8%(95%CI 52.2-72.3%)。研究表明尽管指南强调其重要角色,声门上气道装置在困难气道管理中并未广泛使用。
要点
- 困难气道管理发生率为0.74%,声门上气道装置使用率仅12.4%。
- 声门上气道装置在困难气道管理中成功率为65.1%。
- 无法插管无法面罩通气时声门上气道装置使用率18.9%,成功率62.8%。
核心结论
- 尽管声门上气道装置在困难气道管理指南中占据重要地位,但在实际困难气道管理中并未广泛使用。
研究设计与样本
- 回顾性队列研究,纳入丹麦麻醉数据库2008至2012年658104例成人全麻记录,困难气道定义为≥3次气管插管尝试、气管插管失败或面罩通气困难。
主要发现
- 困难气道管理发生于4898例(0.74%,95%CI 0.72-0.76%)全麻记录中。
- 声门上气道装置在607例困难气道管理中使用或尝试使用(12.4%,95%CI 11.5-13.3%),成功395例(65.1%,95%CI 61.2-68.8%)。
- 在无法插管无法面罩通气情形中,455例记录中86例使用声门上气道装置(18.9%,95%CI 15.6-22.8%),成功54例(62.8%,95%CI 52.2-72.3%)。
临床怎么用
- 临床麻醉医生在困难气道管理中应更积极考虑使用声门上气道装置,尤其在无法插管无法面罩通气时。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Indications for using supraglottic airway devices have widened over time and they now hold a prominent role in guidelines for difficult airway management. We aimed to describe the use of supraglottic airway devices in difficult airway management. We included adult patients undergoing general anaesthesia registered in the Danish Anaesthesia Database from 2008 to 2012 whose airway management had been recorded as difficult, defined as: ≥ 3 tracheal intubation attempts; failed tracheal intubation; or difficult facemask ventilation. In the Danish Anaesthesia Database, a separate difficult airway management module requires the technique used in each successive airway management attempt to be recorded. The primary aim of the study was to describe the use of supraglottic airway devices in cases of difficult airway management. Secondary aims were to examine success rates of supraglottic airway devices in difficult airway management cases, and specifically in the cases of 'cannot intubate, cannot facemask ventilate'. Difficult airway management occurred in 4898 (0.74% (95%CI 0.72-0.76%)) of 658,104 records of general anaesthesia. Supraglottic airway devices were used or use was attempted in 607 cases of difficult airway management (12.4% (95%CI 11.5-13.3%)), and were successful in 395 (65.1% (95%CI 61.2-68.8%)) cases. In 'cannot intubate, cannot facemask ventilate' situations, supraglottic airway devices were used in 86 (18.9% (95%CI 15.6-22.8%)) of 455 records and were successful in 54 (62.8% (95%CI 52.2-72.3%)) cases. We found that supraglottic airway devices are not widely used in the management of the difficult airway despite their prominent role in difficult airway management guidelines.
引用
- Thomsen JLD, Nørskov AK, Rosenstock CV, et al. Supraglottic airway devices in difficult airway management: a retrospective cohort study of 658,104 general anaesthetics registered in the Danish Anaesthesia Database. Anaesthesia. 2018. PMID: 30288736. doi:10.1111/anae.14443
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。