结果显示,GS并未缩短所有新生儿及C&L I-II级新生儿的TTI,但显著缩短了C&L III-IV级新生儿的TTI,并改善了声门视野。

要点

  • GS未缩短所有新生儿及C&L I-II级新生儿的插管时间。
  • GS显著缩短C&L III-IV级新生儿的插管时间。
  • GS改善声门视野,但首次插管成功率无显著差异。

核心结论

  • GS未降低所有新生儿及C&L I-II级新生儿的TTI,但显著降低C&L III-IV级新生儿的TTI。
  • GS提供了更好的声门视野。

主要发现

  • 所有C&L分级新生儿的TTI无显著差异(95%CI -7.36至4.44)。
  • C&L I-II级新生儿(每组n=30)的TTI无差异(95%CI -0.51至5.04)。
  • GS显著缩短C&L III-IV级新生儿的TTI(每组n=5,95%CI 4.94-46.67)。
  • GS改善了声门视野。

临床怎么用

  • 对于C&L III-IV级的新生儿,可考虑使用GS以缩短插管时间并改善声门视野。
  • 对于C&L I-II级的新生儿,GS与DL在插管时间上无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: GlideScope video laryngoscope (GS) has been widely used to facilitate tracheal intubation in adults and pediatric patients because it can improve glottic view. Several investigations performed in pediatric patients have shown that GS provides a better view of the glottis than direct laryngoscope (DL). However, to date, there are no studies assessing the use of GS in neonates. Therefore, we conducted a prospective study to compare time to intubate (TTI) when either GS or DL was used for endotracheal intubation in neonates. METHODS: Seventy neonates (American Society of Anesthesiologists physical status I and II, scheduled to undergo elective surgery under general anesthesia) were randomized to GS group (n = 35) and DL group (n = 35). The primary outcome variable of the study was TTI. As secondary outcomes, success rate of first intubation attempt of all neonates, intubation attempts, and adverse events were also evaluated. The glottic views (depicted by Cormack and Lehane [C&L] grades) obtained with GS and DL were compared. RESULTS: There were no significant differences in TTIs of neonates with all C&L grades (95% CI, -7.36 to 4.44). There was also no difference in the subgroups of neonates with C&L grades I and II (n = 30 each; 95% CI, -0.51 to 5.04). However, GS significantly shortened the TTIs of neonates with C&L grades III and IV compared to DL (n = 5 each group; 95% CI, 4.94-46.67). GS improved the glottic view as compared to DL. Although the total tracheal intubation attempts in the GS group was fewer than that in the DL group (36 vs 41), there was no significant difference (P = .19). CONCLUSIONS: GS use did not decrease the TTI of all neonates and neonates with C&L grades I and II as compared to DL use; however, GS significantly decreased the TTI of neonates with C&L grades III and IV. Additionally, GS use provided improved glottic views.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Tao B, Liu K, Zhao P, et al. Comparison of GlideScope Video Laryngoscopy and Direct Laryngoscopy for Tracheal Intubation in Neonates. Anesth Analg. 2019. PMID: 29985811. doi:10.1213/ANE.0000000000003637

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。