左心室辅助装置植入术后严重右心衰竭的术中血流动力学与超声心动图指标
本研究回顾110例LVAD植入患者,比较术后严重右心衰竭与非严重者的术中右心血流动力学及超声参数。关胸后CVP较高与关胸后及CPB前PAPi较低与严重RVF相关,关胸后CVP和PAPi鉴别严重RVF的AUC均为0.75。
要点
- 关胸后CVP和PAPi鉴别严重RVF的AUC均为0.75(95%CI 0.64-0.86)。
核心结论
- 关胸后CVP和PAPi与严重RVF显著相关。
- CPB后超声评估右室功能与严重RVF仅弱相关。
- 右心衰竭风险评分不是严重RVF的显著预测因素。
研究设计与样本
- 回顾性研究,2013年3月至2016年3月LVAD患者110例。
- 严重RVF定义为需右室机械支持、正性肌力药和/或吸入肺血管扩张剂>14天。
- 计算右心衰竭风险评分并收集右心血流动力学数据。
主要发现
- 110例中25例不符合RVF标准,余85例中28例(33%)符合严重RVF标准。
关键数值与推荐
- 关胸后CVP和关胸后PAPi鉴别严重与非严重RVF的AUC均为0.75(95%CI 0.64-0.86)。
- PAPi计算公式为(肺动脉收缩压-肺动脉舒张压)/中心静脉压。
临床怎么用
- LVAD术中关胸后应关注CVP和PAPi以辅助识别严重RVF高风险患者。
- CPB后超声右室功能指标对严重RVF的关联较弱,解读需谨慎。
局限性
- 回顾性研究,严重RVF定义包含多项治疗要求。
- 超声数据由盲法评价者记录,但研究未报告其他局限性的具体内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. METHODS: A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. RESULTS: A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of severe RVF. Post-chest closure CVP and post-chest closure PAPi discriminated severe from nonsevere RVF better than other variables measured, each with an area under the curve of 0.75 (95% CI, 0.64-0.86). CONCLUSIONS: Post-chest closure values of CVP and PAPi were significantly associated with severe RVF. Echocardiographic assessment of RV function post-CPB was weakly associated with severe RVF.
引用
- Gudejko MD, Gebhardt BR, Zahedi F, et al. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation. Anesth Analg. 2019. PMID: 29878942. doi:10.1213/ANE.0000000000003538
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。