文献速递区域麻醉与超声

实时注射压力监测系统在新鲜尸体中鉴别坐骨神经神经周围与神经内注射的能力

The ability of a real-time injection pressure monitoring system to discriminate between perineural and intraneural injection of the sciatic nerve in fresh cadavers.
PubMed 文献 · Anaesthesia · 2018-06-02

本研究在新鲜尸体中测试一种针尖内置微型压力传感器的新型注射压力监测系统,对坐骨神经进行24次超声引导注射(12次神经周围、12次神经内),以电子泵恒速注射5 ml生理盐水(10 ml.min-1)。排除4次无法确认针尖位置的注射后,神经周围注射的峰值压力显著低于神经内注射(14 (6) kPa vs. 131 (56) kPa;p < 0.001),表明该系统能可靠监测针尖注射压力并鉴别神经周围与神经内注射。

要点

  • 针尖内置压力传感器可实时监测注射压力,神经内注射峰值压力显著高于神经周围注射。
  • 神经周围注射平均峰值压力14 kPa,神经内注射131 kPa,差异有统计学意义(p < 0.001)。
  • 该尸体模型结果支持该系统用于鉴别坐骨神经神经周围与神经内注射。

核心结论

  • 该针尖压力监测系统能准确监测注射压力,在新鲜尸体中可鉴别坐骨神经神经周围与神经内注射。

研究设计与样本

  • 在新鲜尸体中对坐骨神经行24次超声引导注射,12次神经周围、12次神经内,由电子泵恒速注射5 ml生理盐水(10 ml.min-1)。
  • 排除2次神经周围和2次神经内注射,因操作者无法确认针尖准确位置。

主要发现

  • 神经周围注射平均(SD)峰值压力为14 (6) kPa,显著低于神经内注射的131 (56) kPa(p < 0.001)。

关键数值与推荐

  • 神经周围注射平均(SD)峰值压力14 (6) kPa,神经内注射131 (56) kPa,p < 0.001。

临床怎么用

  • 针尖内置压力传感器可实时监测注射压力,辅助鉴别神经周围与神经内注射。

局限性

  • 研究在新鲜尸体模型中进行,结果向临床活体的外推需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Injection pressure monitoring provides valuable information to prevent intraneural injections and possibly consequent nerve damage during peripheral nerve block. However, the measurement of injection pressure along the injection line is inaccurate as it is influenced by several variables. The aim of this study was to test a new system for precise injection pressure monitoring at the needle tip in a cadaveric model. The system consists of a miniaturised pressure sensor embedded within the needle shaft that is connected via an optical fibre to an external control unit. In order to test the capacity of the system to discriminate between perineural and intraneural injections, a total of 24 ultrasound-guided injections at various locations of the sciatic nerve (12 perineural and 12 intraneural) were performed in fresh cadavers. The injections were delivered at a constant rate by an electronic pump (5 ml saline at 10 ml.min-1 ). Two perineural and two intraneural injections were excluded from analysis, since the operator could not confirm the exact needle-tip location. Mean (SD) peak injection pressure was significantly lower for perineural compared with intraneural injections (14 (6) kPa vs. 131 (56) kPa; p < 0.001). This study shows that this system is a reliable method to accurately monitor injection pressure at the needle tip, allowing for discrimination between perineural and intraneural injections of the sciatic nerve in fresh cadavers.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Saporito A, Quadri C, Capdevila X, et al. The ability of a real-time injection pressure monitoring system to discriminate between perineural and intraneural injection of the sciatic nerve in fresh cadavers. Anaesthesia. 2018. PMID: 29858517. doi:10.1111/anae.14330

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。