文献速递区域麻醉与超声

三维打印患者特异性胸椎模型作为触觉任务训练器提高临床熟练度

Improving Clinical Proficiency Using a 3-Dimensionally Printed and Patient-Specific Thoracic Spine Model as a Haptic Task Trainer.
PubMed 文献 · Reg Anesth Pain Med · 2018-01-01

本研究探讨利用患者CT数据制作低成本三维打印胸椎模型用于胸段硬膜外镇痛培训的可行性。13名住院医师使用该模型培训后,与14名传统培训住院医师相比,成功硬膜外置管率显著更高(11 vs 4,P=0.002),且所需指导更少。

要点

  • 患者特异性三维打印胸椎模型可低成本、个性化地用于硬膜外培训。
  • 模型培训组硬膜外成功置管数显著高于传统培训组(11 vs 4)。
  • 模型培训组需上级医师指导的次数更少(1 vs 5)。

核心结论

  • 使用患者特异性三维打印胸椎模型培训可显著提高住院医师胸段硬膜外镇痛的临床熟练度。

研究设计与样本

  • 研究纳入27名住院医师,其中13名接受1小时30分钟的患者特异性三维打印胸椎模型培训,14名接受传统区域麻醉轮转培训,比较胸段硬膜外镇痛成功率。

主要发现

  • 模型培训组成功硬膜外置管11例,传统培训组4例,差异有统计学意义(P=0.002)。
  • 传统培训组需要上级医师指导5例,模型培训组1例。
  • 传统培训组的需治疗人数(NNT)为1.58名患者,95%CI 1.55至1.61。

关键数值与推荐

  • 成功胸段硬膜外镇痛定义为针刺和温度测试评估手术区域感觉完全消失。

临床怎么用

  • 可利用患者CT数据制作低成本三维打印胸椎模型,作为区域麻醉触觉训练工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Advanced haptic simulators for neuraxial training are expensive, have a finite life, and are not patient specific. We sought to demonstrate the feasibility of developing a custom-made, low-cost, 3-dimensionally printed thoracic spine simulator model from patient computed tomographic scan data. This study assessed the model's practicality, efficiency as a teaching tool, and the transfer of skill set into patient care. METHODS: A high-fidelity, patient-specific thoracic spine model was used for the study. Thirteen residents underwent a 1-hour 30-minute training session prior to performing thoracic epidural analgesia (TEA) on patients. We observed another group of 14 residents who were exposed to the traditional method of training during their regional anesthesia rotation for thoracic epidural placement. The TEA was placed for patients under the supervision of attending anesthesiologists, who were blinded to the composition of the study and control groups. As a primary outcome, data were collected on successful TEAs, which was defined as a TEA that provided full relief of sensation across the entire surgical area as assessed by both a pinprick and temperature test. Secondary outcomes included whether any assistance from the attending physician was required and failed epidurals. RESULTS: A total of 27 residents completed the study (14 in the traditional training, 13 in the study group). We found that the residents who underwent training with the simulator had a significantly higher success rate (11 vs 4 successful epidural attempts, P = 0.002) as compared with the traditional training group. The control group also required significantly more assistance from the supervising anesthesiologist compared with the study group (5 vs 1 attempt requiring guidance). The number needed to treat (NNT) for the traditional training group was 1.58 patients over the study period with a 95% confidence interval of 1.55 to 1.61. CONCLUSIONS: By using patient-specific, 3-dimensionally printed, thoracic spine models, we demonstrated a significant improvement in clinical proficiency as compared with traditional teaching models.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Bortman J, Baribeau Y, Jeganathan J, et al. Improving Clinical Proficiency Using a 3-Dimensionally Printed and Patient-Specific Thoracic Spine Model as a Haptic Task Trainer. Reg Anesth Pain Med. 2018. PMID: 29894394. doi:10.1097/AAP.0000000000000821

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。