儿童GlideScope引导气管插管技术困难的前瞻性观察研究
一项在四级儿科医院开展的前瞻性观察研究,观察200例<6岁择期手术患儿的GlideScope引导气管插管,排除经验不足操作者后分析187例患者共225次尝试。58%的尝试存在技术困难,最常发生在声带附近区域(zone 3),导管顺时针旋转是最常见的成功纠正手法;总插管成功率98%,首次尝试成功率仅80%,有技术困难者尝试次数更多。
要点
- 儿童GlideScope插管技术困难发生率为58%(95%CI 51.6%-64.6%)
- 技术困难最常发生在声带附近区域(zone 3),顺时针旋转导管最常成功纠正
- 总插管成功率98%,首次尝试成功率仅80%,技术困难增加插管尝试次数
核心结论
- 多种临床医生在儿童GlideScope Cobalt视频喉镜插管中会遇到技术困难,导致更多插管尝试,而这是插管相关并发症的重要危险因素。
研究设计与样本
- 前瞻性观察研究,2014年2月至8月在四级儿科医院观察200例GlideScope引导气管插管,纳入<6岁择期手术需气管插管患儿,排除经验不足操作者后分析187例患者共225次尝试。
主要发现
- 58%(131/225;bootstrap 95%CI 51.6%-64.6%)的尝试存在技术困难。
- 技术困难最常发生在导管插入杓状软骨平面至刚好超过声带的区域(zone 3)。
- 在zone 3,导管顺时针旋转是最常见的成功纠正手法。
- 总气管插管成功率为98%(95%CI 95%-99%),首次尝试成功率仅80%(95%CI 74%-86%)。
临床怎么用
- 儿童使用GlideScope插管时应关注声带附近区域(zone 3)的技术困难,可尝试顺时针旋转导管作为纠正手法。
- 针对插管困难高发区域进行针对性培训可能减少技术困难的发生。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The GlideScope Cobalt is one of the most commonly used videolaryngoscopes in pediatric anesthesia. Although visualization of the airway may be superior to direct laryngoscopy, users need to learn a new indirect way to insert the tracheal tube. Learning this indirect approach requires focused practice and instruction. Identifying the specific points during tube placement, during which clinicians struggle, would help with targeted education. We conducted this prospective observational study to determine the incidence and location of technical difficulties using the GlideScope, the success rates of various corrective maneuvers used, and the impact of technical difficulty on success rate. METHODS: We conducted this observational study at our quaternary pediatric hospital between February 2014 and August 2014. We observed 200 GlideScope-guided intubations and documented key intubation-related outcomes. Inclusion criteria for patients were <6 years of age and elective surgery requiring endotracheal intubation. We documented the number of advancement maneuvers required to intubate the trachea, the location where technical difficulty occurred, the types of maneuvers used to address difficulties, and the tracheal intubation success rate. We used a bias-corrected bootstrapping method with 300 replicates to determine the 95% confidence interval (CI) around the rate of difficulty with an intubation attempt. RESULTS: After excluding attempts by inexperienced clinicians, there were 225 attempts in 187 patients, 58% (131 of 225; bootstrap CI, 51.6%-64.6%]) of the attempts had technical difficulties. Technical difficulty was most likely to occur when inserting the tracheal tube between the plane of the arytenoid cartilages to just beyond the vocal cords: "zone 3." Clockwise rotation of the tube was the most common successful corrective maneuver in zone 3. The overall tracheal intubation success rate was 98% (CI, 95%-99%); however, the first attempt success rate was only 80% (CI, 74%-86%). Patients with technical difficulty had more attempts (median [interquartile range], 2 [1-3] than those without technical difficulty median (interquartile range, 1 [1-1; P value <.01]). CONCLUSIONS: A variety of clinicians experience technical difficulties with the GlideScope Cobalt videolaryngoscope in children. These difficulties result in more tracheal intubation attempts, an important risk factor for intubation-associated complications. Targeted education of clinicians may reduce the incidence of technical difficulties.
引用
- Zhang B, Gurnaney HG, Stricker PA, et al. A Prospective Observational Study of Technical Difficulty With GlideScope-Guided Tracheal Intubation in Children. Anesth Analg. 2018. PMID: 29750689. doi:10.1213/ANE.0000000000003412
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。