KingVision与C-MAC视频喉镜:嗅物位与中立位插管难易度随机对照试验
这项前瞻性随机临床试验将200例成年患者随机分为四组,比较KingVision(有引导槽)和C-MAC(无引导槽)视频喉镜下嗅物位与中立位对气管插管难易度的影响。主要结局为改良插管困难量表(mIDS)评分,四组间无显著差异(p=0.384);C-MAC中立位组的声门开放百分比(POGO)评分低于其他三组(p=0.01)。结论:两种体位在这两类视频喉镜下插管难易度无显著差异,可根据患者情况选用任一位置。
要点
- KingVision和C-MAC视频喉镜下,嗅物位与中立位的插管难易度(mIDS)无显著差异。
- C-MAC中立位组的POGO评分低于其他三组,但插管时间和成功率无显著差异。
- 临床可根据患者情况选择嗅物位或中立位配合这两类视频喉镜使用。
核心结论
- 使用KingVision和C-MAC视频喉镜时,嗅物位与中立位在插管难易度上无显著差异,两种体位均可选用。
研究设计与样本
- 前瞻性随机临床试验,纳入200例成年患者,随机分为四组:KingVision嗅物位、KingVision中立位、C-MAC嗅物位、C-MAC中立位。
主要发现
- 四组mIDS评分中位数(IQR[范围])分别为0(0-1[0-3])、0(0-1[0-4])、1(0-1[0-5])、0(0-1[0-3]),p=0.384。
- 喉镜暴露时间组间比较p=0.020,插管时间p=0.272,插管成功率p=0.968。
- C-MAC中立位组POGO评分低于其他三组(p=0.01)。
关键数值与推荐
- 主要结局为改良插管困难量表(mIDS)评分,四组间无显著差异(p=0.384)。
- C-MAC中立位组POGO评分低于其他三组(p=0.01),但插管时间(p=0.272)和成功率(p=0.968)无显著差异。
临床怎么用
- 使用KingVision或C-MAC视频喉镜时,可根据患者获益选择嗅物位或中立位,不必强制采用某一特定体位。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Head and neck position is one of the factors which can be associated with difficult videolaryngoscopy and tracheal intubation. This prospective randomised clinical trial compared 'sniffing' and neutral positions using a channelled (KingVision® ) and a non-channelled (C-MAC® D-blade) videolaryngoscope in 200 adult patients randomly allocated into four groups (KingVision 'sniffing', KingVision neutral, C-MAC 'sniffing' and C-MAC neutral). The primary outcome was the ease of tracheal intubation using the modified intubation difficulty scale (mIDS) score. Laryngoscopy time, intubation time, laryngoscopic view using the percentage of glottic opening (POGO) score and success rate of tracheal intubation were secondary outcomes. The median (IQR [range]) modified difficulty scale scores for the four groups, respectively, were 0 (0-1 [0-3]), 0 (0-1 [0-4]), 1 (0-1 [0-5]) and 0 (0-1 [0-3]; p = 0.384). There was no significant difference in laryngoscopy time (p = 0.020), intubation time (p = 0.272) and success rate (p = 0.968) between the groups. The percentage of glottic opening score was lower for C-MAC neutral group as compared with other three groups (p = 0.01). There was no significant difference in the ease of intubation between the 'sniffing' and the neutral position when using the KingVision and the C-MAC videolaryngoscopes. Therefore, either of the two positions could be used with these types of videolaryngoscopes, if deemed advantageous for the patient.
引用
- Mendonca C, Ungureanu N, Nowicka A, et al. A randomised clinical trial comparing the 'sniffing' and neutral position using channelled (KingVision® ) and non-channelled (C-MAC® ) videolaryngoscopes. Anaesthesia. 2018. PMID: 29660807. doi:10.1111/anae.14289
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。