严重肥胖与妊娠晚期未临产产妇环甲膜深度的关系:一项前瞻性观察研究
这项前瞻性观察研究用超声测量15名严重肥胖(BMI>45 kg m-2)与15名正常体重(BMI≤25 kg m-2)妊娠晚期未临产产妇的环甲膜深度,发现严重肥胖组在头后仰、无探头压力、横切面下平均深度18.0 mm,显著大于非肥胖组的10.6 mm,平均差7.4 mm。
要点
- 严重肥胖产妇环甲膜深度平均18.0 mm,比正常体重者深7.4 mm。
- 无论扫描切面、头颈位置或探头压力如何,肥胖组环甲膜深度均增加。
- 超声测量环甲膜深度观察者间信度优秀,可辅助肥胖产妇FONA准备。
核心结论
- 严重肥胖产妇环甲膜深度较正常体重产妇显著增加,且不受扫描切面、头颈位置或探头压力影响。
研究设计与样本
- 前瞻性观察研究,纳入15名严重肥胖(BMI>45 kg m-2)和15名正常体重(BMI≤25 kg m-2)妊娠晚期未临产产妇,由两名麻醉医师行气道超声。
主要发现
- 横切面、头后仰、无探头压力下环甲膜深度:严重肥胖组平均18.0 mm(95%CI 16.3-19.8),非肥胖组10.6 mm(8.81-12.4),P<0.001。
- 平均差7.4 mm(95%CI 4.9-9.9),P<0.001。
- 其他扫描切面、头颈位置或探头压力配置下,严重肥胖组环甲膜深度均增加(所有P<0.001)。
- 观察者间信度优秀。
临床怎么用
- 对严重肥胖妊娠晚期产妇,应预期环甲膜深度增加,FONA时需考虑更深穿刺路径。
- 床旁超声可用于测量环甲膜深度,辅助肥胖产妇FONA定位与准备。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Severely obese parturients have increased 'cannot intubate, cannot oxygenate' risk during Caesarean section under general anaesthesia. Front-of-neck access (FONA) at the cricothyroid membrane (CTM) is definitive management; however, attempted FONA can fail. Point-of-care ultrasonography may provide useful information about CTM depth to aid FONA in obesity. This study determined the difference in CTM depth between severely obese and non-obese parturients, utilising ultrasonography. METHODS: In this prospective observational study, two anaesthetists performed airway ultrasonography on 15 severely obese (BMI >45 kg m-2) and 15 normal-weight (BMI ≤25 kg m-2) parturients in the third trimester, using the transverse and longitudinal planes, sniffing and extended head positions, and nil and firm transducer pressures. The primary outcome was CTM depth (millimetres) measured in the transverse plane with the head extended and nil transducer pressure. Secondary outcomes included CTM depth measurements using other factor configurations. Intra-class correlation coefficients assessed the inter-observer reliability. RESULTS: CTM depth measured in the transverse plane with head extended and nil transducer pressure was significantly greater in severely obese parturients, mean 18.0 mm (95% confidence interval 16.3-19.8), vs 10.6 mm (8.81-12.4) in non-obese (P<0.001); mean difference 7.4 mm (4.9-9.9; P<0.001). CTM depths were increased in the severely obese group regardless of scanning plane, head and neck position, or transducer pressure (all P<0.001). There was excellent inter-observer reliability. CONCLUSIONS: Cricothyroid membrane depth is significantly increased in severely obese vs normal-weight parturients independently of scanning plane, head and neck position, or transducer pressure.
引用
- Gadd K, Wills K, Harle R, et al. Relationship between severe obesity and depth to the cricothyroid membrane in third-trimester non-labouring parturients: a prospective observational study. Br J Anaesth. 2018. PMID: 29661380. doi:10.1016/j.bja.2018.02.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。